My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1064
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1064
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2022 3:00:58 PM
Creation date
5/26/2022 3:00:56 PM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1064
Building Department - Name
DR HORTON
Address
6610 COBBLE BLISS ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017' INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar. Below <br /> 1 N=>W. Exterior Concrete Block-Int Insul Main 4.0999 20 4 9 4 189.8 ft2 0 0.6 0 <br /> 2 E=>N Exterior Concrete Block.-Int Insul Main - 4.0999 64 1 9 4 598.1 ft2 0 0.6 0 <br /> 3 S=>E Exterior Concrete Block-Int Insul Main 4.0999_ 50 0 9 4 466.7 ft2 0 .0.6 0 <br /> 4 W=>S Exterior Concrete Block-Int Insul Main 4.0999 74 0 9 4 690.7 ft2 0 0.6 0 <br /> 5 N=>W Garage Frame-Wood Main 13 29 0 9 4 270.7 ft2 0.23 0.01 0 <br /> 6 W=>S Garage Frame-Wood Main 13 2 0 - 9 4 18.7 ft2 0.23 0.01 0 <br /> 7 E=>N Garage Frame-Wood Main 13 11 2 9 4 104.2 ft2 0.23 0.01 0 <br /> DOORS. <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft - In <br /> 1.. N=>W. Insulated Main None .4 3 8 24 f0 <br /> 2 N=>W Wood Main . None .46 2 8 8 .21.3 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). <br /> Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 30.0 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 <br /> 2- E=>N 2 Vinyl Low-E Double Yes 0.34 0.31 N 45.0 ft2 1 ft 0 in Oft 11 in None Exterior 5 <br /> 3. E=>N 2 Vinyl Low-E Double. Yes 0.34 0.31 N 18.0 ft2 1 ft 0 in 0 ft 11 in None Exterior 5 <br /> 4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 45.0 ft2 1 ft 0 in Oft 11 in None Exterior 5 <br /> 5 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 22.5 ft2 1 ft 0 in 0 ft 11 in None Exterior 5 <br /> 6 S=>E 3 Metal Low-E Double Yes 0.55 0.34 N 72.0 ft2 10 ft 0 in 0 ft 2 in None Exterior 5 <br /> 7 W=>S 4 Vinyl Low-E Double .Yes 0.34 0.31 N 22.5 ft2 19 ft 4 in 0 ft 2 in None Exterior 5 <br /> 8 W=>S 4 Vinyl Low-E,Double Yes 0.34 0.31 N 75.0 ft2 1 ft 0 in Oft 11 in None. Exterior 5 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> .1 619.13ft2 619.13ft2 62.2ft 9.3ft 0. <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000414 3077.1 168.93 317.69 .1609 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Speed Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ None. Sing[ HSPF:8.5 42 kBtu/hr 1, sys#1 <br /> 8/10/2020 1:30 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017.FBC 6th Edition(2017) Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.