23. Tamper- Resistant.Receptacles in accordance with 406.11 of.the 201.6 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure: <br /> 25.-R403.5,3Hot water pipe insulation. <br /> Insulation for hot water pipe-with'a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping:3/;inch (19.1 mm) and larger in.nominal diameter. <br /> Piping serving more than:one dwelling unit: <br /> Piping Located outside the conditioned space: <br /> Piping from the'water heater to.a distribution manifold; <br /> Piping:located under.a floor slab,. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25:-Blower:door test shag be provided before C.O. <br /> 26.A copy of the enemy cacls shall be with'permit at all times <br /> 27.. Cope ofTnahinsuladon report shall be provided ivith permit before final <br /> 28. No fence, pool or screen enclosure :is issued with:this.permit` <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C--Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric Code(2016) <br />