Laserfiche WebLink
FORM R405-2017 STATE COPY <br /> FLORIDA ENERGY EFFICIENCY CODE FOR-BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KH02743 Ivanhoe(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6872 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: FL, 33542 Permit Number: - <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2785.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1312.00 ft' <br /> b.Concrete Block:'Int Instil,Exterior R=4.1 1-112.20 ft' <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 361.11 ft' <br /> 4. Number of Bedrooms 5 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1610.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1610.00 ft: <br /> 6.. Conditioned floor area above grade(ft� 2666 b.N/A R= ft' <br /> Conditioned floor area below grade(ft2) 0 c. R= ft' <br /> 11.Duct <br /> s R ft' <br /> 7. Windows(211.1 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 274.3 <br /> a. U-Factor. Dbl,U=0.34 109.75 ft' <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.34 61.19 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.29 a.Central Unit 33.1 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.63 40.20 ft' <br /> SHGC: SHGC=0.32 13.Heating systems kStu/hr Efficiency <br /> d. U-Factor: N/A ft' a.Electric Heat Pump 32.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.265 14.Hot water systems <br /> 8. Floor Typ es 2666.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> ( <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1131.00 ft' b. Conservation features <br /> b.Floor Over Other Space R=0.0 1056.00 ft' None <br /> c.other(see details) R= 479.00 ft' 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 81.39 <br /> Total Baseline Loads: 81.34 PASS <br /> I hereby certify that the plans and specifications covered by Review of the plans and OvaE sz; <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY- /1 /� Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> 1 herebycertifythat this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. g0D` <br /> WE <br /> OWNER/AGENT: Scu-a71.i2iyera/ BUILDING OFFICIAL: <br /> DATE: 11-13-2020 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 5.80 ACH50(R402.4.1.2). <br /> 11/13/2020 8:59 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 <br />