Laserfiche WebLink
STATE COPY <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KH02127 Palmera(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6880 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: FL, 33542 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1908.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1636.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 271.56 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2127.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2127.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2127 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(174.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 273 <br /> a. U-Factor: Dbl,U=0.34 118.12 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.63 40.00 ft2 12.Cooling systems kBtu/hr Efficiency" <br /> SHGC: SHGC=0.32 a.Central Unit 33.1 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.34 16.19 ft2 <br /> SHGC: SHGC=0.29 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 3.295 ft. <br /> Area Weighted Average SHGC: 0.266 14.Hot water systems <br /> 8. Floor Types (2127.0 sqft.) Insulation Area a. Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 2127.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.082 Total Proposed Modified Loads: 65.69 PASS <br /> Total Baseline Loads: 66.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O AjIE S7,q�� " <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,� __ ,. •Off, <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: .�/�/.R/e� Before construction is completed wl� �, <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. - <br /> with the Florida Energy Code. <br /> OWNER/AGENT:- SARAH RIVE'RA BUILDING OFFICIAL: <br /> DATE: 11/12/2020 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 9/30/2020 11:11 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />