Laserfiche WebLink
STATE COPY <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business arid Professional Regulation - Residential Performance Method <br /> Project Name: KH02127 Palmera(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6857 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: FL, 33542 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1907.4 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1635.80 ft' <br /> b. Frame-Wood,Adjacent R=11.0 271.56 ft' <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4. Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2127.0 sqft.) Insulation Area <br /> a. Under Attic(Vented) R=30.0 2127.00 ft' <br /> 6. Conditioned floor area above grade(ft') 2127 b.N/A R= ft' <br /> Conditioned floor area below grade(ft') 0 c.N/A R= ft' <br /> 11.Ducts R ft' <br /> 7. Windows(174.3 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 273 <br /> a. U-Factor: Dbl,U=0.34 118.12 ft' <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.63 40.00 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 33.1 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.34 16.19 ft' <br /> SHGC: SHGC=0.29 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft' a.Electric Heat Pump 32.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.256 14.Hot water systems <br /> 8. Floor Types (2127.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2127.00 ft' b. Conservation features <br /> b.N/A R= ft' None <br /> c.N/A R= ft' 15.Credits Pstat <br /> Glass/Floor Area: 0.082 /"��7�7 <br /> Total Proposed Modified Loads: 66.34 PASS <br /> C C <br /> Total Baseline Loads: 66.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O&Zf16 ST•q?F <br /> this calculation are in compliance with the Florida Energy specifications covered by this *' _ p� <br /> �y <br /> Code. calculation indicates compliance <br /> with the Flofida Energy Code. <br /> yv J <br /> PREPARED BY: Before construction is completed � �:�-� '•' .-• <br /> DATE: ?.W� - v <br /> -28- 20 this building will be inspected for <br /> compliance with Section 553.908 * a <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. V G'pD <br /> OWNER/AGENT: Saval►.►2 ye-ct. BUILDING OFFICIAL: <br /> DATE: 11/12/2020 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 9/30/2020 11:08 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />