Laserfiche WebLink
r <br /> Single .Family Dwelling . <br /> Plan Review Comments <br /> 1. FXX shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2! Lots shall be graded to comply with R401.3 of the F:B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one-place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways'require a R.O.M. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be"met. <br /> 7. All property markers shall be uncovered.and marked At time of first inspection. <br /> 8: All A.D.A. requirements shall be' met: <br /> 9. No electric,plumbing,mechanical"or framing shall be:covered without an inspection and . <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to:meclianicai damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> II.Water heaters shall comply with section P607.3 of the F.B*C.. <br /> 13:Foundation supports for A/C units.-shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms: F.B.C.: M.16204 <br /> 15. Smoke detectors are to be.installed iri"accordance with R313.1 of the F.B.C. <br /> 16: All"glazing requirements are to be in accordance with R308:4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.&C.. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4:2 F.B.C. <br /> 19..Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. . <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> - or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit: This includes,all <br /> underground.plumbing and electric. <br /> 22. All 2016 N:E.C. Codes will be enforced: <br />