Laserfiche WebLink
Single Phase Inverter <br /> with HD-Wave Technology for Borth America <br /> SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ <br /> SE760OH-US / SE1000OH-US / SE1140OH-US <br /> OUTPUT <br /> Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA <br /> 3300 @ 208V 5000 @ 208V 10000 @ 208V <br /> Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA <br /> 3300 @ 208V 5000 @ 208V 10000 @ 208V <br /> AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac <br /> (211-240-264) <br /> AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac <br /> (183-208-229) <br /> AC Frequency(Nominal) 59.3-60-60.501 Hz <br /> Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A <br /> Maximum Continuous Output - 16 - 24 - 48.5 A <br /> Current @208V <br /> GFDI Threshold 1 A <br /> Utility Monitoring,Islanding Protection, <br /> Country Configurable Thresholds Yes <br /> INPUT <br /> Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W <br /> Maximum DC Power @208V - 5100 7750 15500 W <br /> Transformer-less,Ungrounded Yes <br /> Maximum Input Voltage 480 Vdc <br /> Nominal DC Input Voltage 380 400 Vdc <br /> Maximum Input Current @240Va1 8.5 10.5 13.5 16.5 20 27 30.5 Adc <br /> Maximum Input Current @208V91 - 9 13.5 - 27 Adc <br /> Max.Input Short Circuit Current 45 Adc <br /> Reverse-Polarity Protection Yes <br /> Ground-Fault Isolation Detection 60042 Sensitivity <br /> Maximum Inverter Efficiency 99 99.2 <br /> CEC Weighted Efficiency 99 9 98. @ 240V % <br /> 5 @ 208V <br /> Nighttime Power Consumption <2.5 W <br /> ADDITIONAL FEATURES <br /> Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) <br /> Revenue Grade Data,ANSI C12.20 Optional") <br /> Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect <br /> 2017 690.12 <br /> STANDARD COMPLIANCE <br /> Safety UL1741,UL1741 SA,U1.169913,CSA C22.2,Canadian AFCI according to TI.L.M-07 <br /> Grid Connection Standards EEE1547,Rule 21,Rule 14(HI) <br /> Emissions FCC Part 15 Class B <br /> INSTALLATION SPECIFICATIONS <br /> AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG V Maximum/14-4 AWG <br /> DC Input Conduit Size/#of Strings/AWG Range 1"Maximum/1-2 strings/14-6 AWG 1'Maximum/1-3 strings/14-6 AWG <br /> (HxWxD Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 I mm <br /> Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg <br /> Noise <25 <50 dBA <br /> Cooling Natural Convection <br /> Operating Temperature Range -13 to+140/-25 to+601'i(-40°F/-40'C option)isl <br /> Protection Rating NEMA 4X(Inverter with Safety Switch) <br /> For other regional settings please contact SolarEdge support <br /> m A higher current source may be used;the inverter will limit its input current to the values stated <br /> �Revenue grade inverter P/N:SExxxxH-US000NIJC2 <br /> For power de-rating information refer to-https//www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf <br /> n1-40 version P/N.SExxxxH-US000NNU4 <br /> 7 SolarEdge Technologies.Inc All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All �®�9 <br /> other trademarks mentioned herein are trademarks of their respective owners.Date:03/2019/V01/ENG NAM.Subject to change without notice. H <br />