Laserfiche WebLink
FORM R405-2020 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Rossello-5424 10th St Builder Name: 3�t�� ( 1 V l" <br /> Street: 5424 10th St Permit Office: Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: II <br /> Owner: Jurisdiction: 61�6D0 <br /> Design Location: FL,Lakeland County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing Addition 10. Wall Type41667.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Detached a.Frame-Wood,Exterior R=13.0 1667.50 ft' <br /> b.N/A R= ft' <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4. Number of Bedroom�Bedrms In Addition) 2(0) d.N/A R= ft' <br /> 11.Ceiling Types (1451.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1451.00 ft' <br /> 6. Conditioned floor area above grade(ft') 1451 b.N/A R= ft' <br /> Conditioned floor area below grade(ft') 0 c. R= <br /> 7. Windows(136.3 sqft.) Description Area 12.Ducts R ft' <br /> a. U-Factor: Dbl,U=0.34 136.31 ft' a.Sup:Laundry,Ret:Laundry,AH:Laundry 6 287 <br /> SHGC: SHGC=0.21 <br /> b. U-Factor: N/A ft' 13.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft' <br /> SHGC: 14.Heating systems kBtu/hr Efficiency <br /> Area Weighted Average Overhang Depth: 2.817 ft. <br /> Area Weighted Average SHGC: 0.210 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> 8. Skylights Area <br /> c. U-Factor:(AVG) N/A ft' 15.Hot water systems-Replacement equipment <br /> SHGC(AVG): N/A a.Electric Cap:40 gallons <br /> 9. Floor Types (1451.0 sqft.) Insulation Area EF:0.950 <br /> a.Raised Floor R=13.0 1451.00 ft' b. Conservation features <br /> b.N/A R= ft' None <br /> c.NIA R= ft' 16.Credits Pstat <br /> Glass/Floor Area: 0.094 Total Proposed Modified Loads: 41.25 PASS <br /> Total Baseline Loads: 47.63 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O�THE Sr <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. rr�r, � :° ';�•;�.��,,�O <br /> PREPARED BYC'0_14� 5tizz6g"Z' E-Calcs Plus, In Before construction is completed <br /> DATE: February 5.2021 this building will be inspected for a <br /> compliance with Section 553.908 ° <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. CAD WE <br /> OWNER/AGENT: BUILDING OFF AL• <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).(Exception may apply) <br /> 2/5/2021 11:07 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5 <br />