My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1119
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1119
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2022 8:02:13 AM
Creation date
5/27/2022 8:02:11 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-1119
Building Department - Name
ROSSELLO ANGELO & RUTH E LIVING TRUST
Address
5424 10TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM•R405-2020 INPUT SUMMARY CHECKLIST REPORT <br /> WINDOWS <br /> Orientation shown is the entered,Proposed orientation. <br /> Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 E 1 Vinyl Low-E Double Yes 0.34 0.21 N 12.4 ft2 2 ft 0 in 0 ft 6 in None None <br /> 2 S 2 Vinyl Low-E Double Yes 0.34 0.21 N 18.0 ft2 2 ft 0 in 0 ft 6 in None None <br /> 3 N 8 Vinyl Low-E Double Yes 0.34 0.21 N 12.4 ft2 2 ft 0 in 0 ft 6 in None None <br /> 4 N 9 Vinyl Low-E Double Yes 0.34 0.21 N 7.0 ft2 2 ft 0 in 0 ft 6 in None None <br /> 5 N 9 Vinyl Low-E Double Yes 0.34 0.21 N 24.7 ft2 2 ft 0 in 0 ft 6 in None None <br /> 6 S 10 Vinyl Low-E Double Yes 0.34 0.21 N 37.1 ft2 2 ft 0 in 0 ft 6 in None None <br /> 7 W 11 Vinyl Low-E Double Yes 0.34 0.21 N 12.4 ft2 2 ft 0 in 0 ft 6 in None None <br /> 8 W 11 Vinyl Low-E Double Yes 0.34 0.21 N 12.4 ft2 11 ft 0 in 0 ft 6 in None None <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000427 1625.1 89.16 167.39 .132 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Speed Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/Replacem Split Singl HSPF:8.2 28.6 kBtu/hr 1 sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit/Replacement for Split Singl SEER: 14 28.6 kBtu/hr cfm 0.7 1 sys#1 <br /> HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Laundry 0.95 40 gal 50 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ft2 <br /> DUCTS <br /> --Supply-- --Return-- Air CFM 25 CFM25 HVAC# <br /> V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 Laundry 6 287 ft2 Laundry 71 ft2 Default Leakage Laundry (Default) (Default) 1 1 <br /> 2/5/2021 11:07 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.