Laserfiche WebLink
21 Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots_ shall be sodded before final at least_ 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> insulation for hot water pipe with.a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 1,h inch (19.1 mm)and larger in nominal diameter, <br /> Piping serving more than.one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution manifold. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided.liefore' C.O; <br /> 26.A copy of the energy cacls shall be with permit at all times <br /> 27. Cope of rMaI'ihsulation-ieyort shalhbe provided with permit before fnaL <br /> 28. No fence, pool or screen-enclosure is-issued with this permit <br /> F.F.H.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6ffi Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />