• Application instructions (cont.) -- <br /> •Shearvalues-for panels applied directlyto studs shall be no greater CONDITION CORRECTION-- <br /> than noted in Table 1_of the ICC-ES.Report ESR 1301 or Table 1'of. <br /> APA PR-N124. Snug ® OK -- -- --Not warranted for application on SIP and ICF assemblies. Flush Oic <br /> CAUTION Visible fiber . . �_ paint. <br /> •38 and 76 Series panels must be installed on 16 inch o.c.framing Countersunk Apply sealant <br /> only.When installing on 24 inch o.c.framing,190 Series panels are <br /> required. Countersunk more' Apply sealant and <br /> Backside of panel mustnot come in contact with.masonry or than Va in.. re-nail <br /> concrete foundation. . <br /> •Do not force siding into place.Maintain.the illustrated 1/8 inch <br /> space behind the lolrit to allow for.expansion while the panel 1 IN. ROOF & CHIMNEY CLEAR, <br /> equilibrates with the local environment. <br /> •.LP®SmartSide°Panel.siding must not be attached by.stapiing. <br /> •00 NOT INSTALL OVER ALIGNMENT BEAD.Install panels In light <br /> contact to the edge.of alignment bead..(see Figure 1 and Figure 2) <br /> Climb cut the surface of the.siding such that the rotation of the blade <br /> cuts downward on the primed or'prefinished surface. _—Trim, <br /> • Where siding buttsv+iindowtrim,door casings and masonry;etc,leave. <br /> a 3116 inch gap and seal. <br /> Insulated Sheatthings: <br /> LP SmartSide Sidings may be Installed over.low-compression rigid: 41n.rein.vertical 'M'�•. Prime and paint <br /> foam or exterior gypsum-.The following precautions must be followed:' flashing ., bottomdrlp <br /> 1 in.min:. edges:. <br /> a)Adequate bracing of the•wall in accordance with the International clearance from ''- <br /> Codes'or'other ruling building code•is required. roofing <br /> b)For rigid_foam sheathing up to 1 inch(25A mm)thick,siding <br /> may be nailed directly to the foam sheathing unless a drainage <br /> plane.is required by.the local building code:Nall length must be Flg6re4 <br /> increased to ensure a minimum 1-1/2 inch(38.1 mm).fastener <br /> penetration into the structural framing. <br /> c)For rigid foam sheathing greater than 1 inch USA i*m),a minimum , . , SIDING JOINT DETAILS <br /> 14/2 inch(38 1 mm)thick by 3-1/2 inch(88.9 mm)wide.vertical <br /> strapping or furringstrip must be installed over the sheathing to <br /> provide a solid,level nailing base for the siding.The strapping must HORIZONTAL WALL JOINTS <br /> be securely fastened to structural framing spaced no greater than BUTT 6 FLASH_ LAP <br /> 19 inches o.c.(406'mm)with a minimum nail penetration of 1-1/2 Sldin <br /> Inches(38.1 min)and a maximum nails spacing no reater than the 3 Siding g Blocking <br /> P g g /8 in. Blocking <br /> width of the siding. min.gap g <br /> Louisiana-Pacific will assume no responsibility for any damage or <br /> n <br /> condition arising from the use of rigid foam or exterior_gypsum. 1 in.min. <br /> Sloped overlap Lap panel <br /> 'flashingwith . over bottom <br /> _. 4 in.vertical leg. panel <br /> . Nall 3/8 in, <br /> from edge Figure 5A Figure SB <br /> • ' 12 in.max. LAPPED HORIZONTAL WALL JOINT <br /> field nailing Siding <br /> 6 in.max. ' <br /> perimeter kFraming(band joist, <br /> Gin.'max. nailing truss chard,etc.). <br /> pedineter.nailing 1 <br /> in.min, Wall Framing <br /> overlap <br /> Do:not let panel 6 in:min.ground <br /> contact masonry clearance . <br /> Foundation Figure SC <br /> Figure 3 <br />