Laserfiche WebLink
SYSTEM SPECIFICATIONS <br /> System Capacity. Temperature and Humidity Ranges <br /> • Annunciators......................................................................8 This system meets NFPA requirements for operation at 0- <br /> 49°C/32 — 120°F and at a relative humidity.93% t 2% RH <br /> Electrical Specifications (noncondensing) at 32°C t 2°C (90°F t 30F). However, the <br /> useful life of the system's,standby batteries and the-electronic <br /> • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, components may be adversely affected by extreme tempera- <br /> 1.0 A ture ranges and humidity.- Therefore, it is recommended that <br /> • MS-10UD-7 (FLPS-7 Power. Supply): 120 VAC, 60 HZ, this system and its peripherals be installed in an environment <br /> 3.90 A with a normal room temperature of 15—27°Ci60—80°F. <br /> • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, <br /> 0.54 A. Agency Listings and Approvals <br /> MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, The listings and approvals below apply to the basic MS-5UD-3 <br /> 2.20 A. and MS-10UD-7 control panels. In some cases, certain mod- <br /> • Wire size: minimum 14 AWG (2.0 mm2).with 600 V insula- ules or applications may not be listed 'by certain approval <br /> tion,supervised_,nonpower-limited agencies, or listing may in process. Consult factory for lat- <br /> est listing status. <br /> Cabinet Specifications • UL Listed:File S624 <br /> Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x • FM Approved <br /> 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.)-high x • CSFM:7165-0075:0214 <br /> 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep.Trim Ring . MEA: MEA:333-07-E <br /> (TR-CE):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. <br /> NOTE.For ULC-listed,models,see DF-60440. . <br /> Shipping Specifications NFPA Standards <br /> Dimensions: <br /> The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- <br /> lowing NFPA 72 Fire Alarm Systems requirements: <br /> —22.5 (57.15 cm.)wide —LOCAL (Automatic, Manual, Waterflow and Sprinkler <br /> 8.5"(21.59 cm.)deep. Supervisory). <br /> Weight:27 lb(12.20 kg) —AUXILIARY(Automatic, Manual and Waterflow) (requires <br /> 4XTMF). <br /> —REMOTE STATION (Automatic, Manual and Waterflovu) <br /> (Where a DACT is not accepted, the alarm, trouble and . <br /> supervisory relays may:be connected to UL 864 listed <br /> transmitters. For reverse polarity signaling of alarm and <br /> trouble,4XTMF is required.) <br /> —PROPRIETARY(Automatic,Manual and Waterflow). <br /> —CENTRAL STATION (Automatic, Manual and Waterflow, <br /> and Sprinkler Supervised). <br /> -PT, PSDN (Other Technologies, Packet-switched Data <br /> Network) <br /> FireLite® Alarms and System Sensor® are registered trademarks of <br /> Honeywell International Ind." <br /> ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> of this document is strictly prohibited. <br /> This document is not intended to be used for installation purposes. <br /> 1 S 0 9001 We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements:- <br /> ENCINBIN®8 A7ANUFACTIIIIING All specifications are subject to change without notice. <br /> QUALITY SYSTEMS Made in the U.S.A. <br /> For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. <br /> www.firelite.com <br /> Page 4 of 4—DF-524160.67/26/2010 <br />