My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1168
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1168
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 2:14:19 PM
Creation date
6/1/2022 7:57:55 AM
Metadata
Fields
Template:
Building Department
Company Name
SOUTHSIDE CHURCH OF CHRIST
Building Department - Doc Type
Permit
Permit #
20-1168
Building Department - Name
SOUTHSIDE CHURCH OF CHRIST
Address
37737 C AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DF-52417:D•B-90 <br /> ANN-80 � Flre•LITe®ALarms <br /> SO-Character.Serial LCD Annunciator by Honeywell <br /> Annunciators <br /> General <br /> The ANN-80 annunciator is a compact, backlit, 80-character LCD <br /> fire annunciator that mimics the Fire Alarm Control Panel (FACP) <br /> display. It provides system status indicators for AC Power, Alarm, <br /> Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employ At A <br /> - <br /> ing the ANN-Bus communication format. Connected devices are IQt <br /> powered, via two additional wires, by either the host FACP or a <br /> remote UL-listed, filtered power supply. The ANN-80 is red; for <br /> white, order ANN-80-W. <br /> The ANN-80 displays English-language text of system point informa- <br /> tion including device type,zone,independent point alarm,trouble or <br /> by,Honeywell <br /> supervisory status,as well as any custom alpha labels programmed <br /> into the control panel. It includes control switches for remote control <br /> of critical system functions. (A keyswitch prevents unauthorized <br /> operation of the control switches.) <br /> Up to eight ANN-80s may be connected to the ANN-Bus of each <br /> FACP.No programming is required,which saves time during system <br /> commissioning. <br /> Features Supervisory . <br /> • Alarm Silenced <br /> • Listed to UL Standard 864,9th Edition <br /> • Backlit 80-character LCD display(20 characters x 4 lines) Specifications <br /> • Mimics all display information from the host panel Operating voltage range: 18 VDC to 28 VDC <br /> • Control switches for System Acknowledge, Signal Silence, Drill, Current consumption @ 24 VDC nominal (filtered and non- <br /> and Reset resettable):40 mA maximum <br /> • Control switches can be independently enabled or disabled at the Ambient temperature:32°F to 120°F(0°C to 49°C) <br /> FACP Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± <br /> • Keyswitch enables/disables control switches and mechanically 2°C(90°F t 3°F) <br /> locks annunciator enclosure 5.375"(13.65 cm.)high x 6.875"(17.46 cm.)wide x 1.375'(3.49 <br /> • Keyswitch can.be enabled or disabled at the FACP cm.)deep <br /> • Enclosure supervised for tamper For use indoors in a dry location <br /> • System status LEDs for AC Power,Alarm, Trouble, Supervisory, All connections are power-limited and supervised <br /> and Alarm Silence <br /> • Local sounder can be enabled or disabled at the FACP The ANN-Bus <br /> • ANN-80 connects to the ANN-Bus terminal on the FACP and <br /> requires minimal panel programming POWERING THE DEVICES ON THE ANN-BUS FROM AUX/L- <br /> • Displays device type identifiers, individual point alarm, trouble, IARY POWER SUPPLY <br /> supervisory,zone,and custom alpha labels The ANN-Bus can be powered by an auxiliary power supply when <br /> • Time-and date display field the maximum number of ANN-Bus devices exceeds the ANN-Bus <br /> • Surface mount directly to wall or to single, double, or 4" square power requirements.See the FACP manual for more information. <br /> electrical box ANN-BUS DEVICE ADDRESSING <br /> • Semi-flush mount to single,-double, or 4" square electrical box. Each ANN-Bus device requires a unique address (ID Number) in <br /> Use ANN-SB80KIT for angled view mounting order to communicate with the FACP.A maximum of 8 devices can <br /> • Can be remotely located up to 6,000 feet (1,800 m) from the be connected to the FACP ANN-Bus communication circuit.See the <br /> panel FACP manual for more information. <br /> • Backlight turns off during AC loss to conserve battery power but WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT <br /> will turn back on if an alarm condition occurs <br /> • May be powered by 24 VDC-from the host FACP or by remote 'The ANN-80 connects to the FACP ANN-Bus communications cir- <br /> power supply(requires 24 VDC) cuit.To determine the type of wire and the maximum wiring distance <br /> • Up to eight ANN-80s can be connected on the ANN-Bus that can be used with FACP ANN-Bus.accessory modules, it is nec- <br /> essary to calculate the total worst case current draw for all modules <br /> on a single 4-conductor bus. The total worst case current draw is <br /> Controls and Indicators on <br /> by adding the individual worst case currents for each <br /> • AC Power module. <br /> • Alarm NOTE:For total"worst case current draw on a single ANN-Bus refer to <br /> • Trouble appropriate FACP manual. <br /> DF-524170•3/15/2018—Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.