Common Specifications <br /> Environmental;Temperature and Humidity 32"to 122"F(0°to 50"C);10%to 93%,non-condensing at 100"F(38"C) <br /> Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per <br /> terminal for in/out wiring <br /> Speaker Specifications <br /> Input Voltage 25 or 70.7 VRMS,see Note 1 below <br /> Power Taps 1/4, 1/2,1,and 2 W <br /> Frequency Response Fire Alarm 400 to 4000 Hz <br /> General Signaling 125 to 12 kHz <br /> Wattage Tap 1/4 W: .1,12 W. 1 W 2.W. <br /> Speaker Output Ratings <br /> @ 10 ft(3 m) Reverberant Chamber, 76 dBA 79 dBA 82 dBA 85 dBA <br /> UL 1480Test <br /> (see Note 1 below) Anechoic Chamber, 87 dBA 90 dBA 93 dBA 96 dBA <br /> 1 kHz Input,On-Axis <br /> Strobe Specifications <br /> Rated Voltage Range UL Listed Rating Regulated 24 VDC;see Note 2 below <br /> ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 <br /> Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC <br /> Housing Dimensions(with lens) 7-1/4"H x 5"W x 2-5/8"D(184 mm x 127 mm x 67 mm) <br /> Maximum RMS Current Rating per 15.cd 30 cd . - --,75 cd,.. 110 cd <br /> Wall Strobe Setting(see Note 3 below) 60 mA 94 mA 186 mA 252 mA <br /> Mount <br /> Reference RMS Currents at .18 VDC 53 mA 84_rhA ' 165 rrA 224 mA <br /> other woltages. 24 VDC 40-mA,1:- 63 mA.. '. '124 mA. 168 mA <br /> Housing Dimensions Speaker housing=7-1/2"(191 mm)diameter,1/2"deep(13 mm);lens protrusion <br /> above speaker housing=2-5/8"(67 mm);depth into box=2-3/4"(70 mm) <br /> Ceiling Maximum RMS Current Rating per 15-cd 30 cd 75 cd 110 cd . <br /> - Mount Strobe Setting(see Note 3 below) 75 mA 125 mA 233 mA 316 mA <br /> Reference RMS Currents at' '18 VDC 67 rnk 111-mA 207 mA 281 mA <br /> other voltages 24 VDC 50 mA —83 mA:-. 155 mA.: . : 211 mA <br /> NOTES: <br /> 1. Speakers are for connection to conventional fire alarm audio circuits.Anechoic speaker output ratings are typically more representative <br /> of actual installed sound output. <br /> 2. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired, <br /> changes effective May 1,2004.This voltage range is the absolute operating range.Operation outside of this range may cause <br /> permanent damage to the appliance.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on <br /> the NAC under worst case conditions. <br /> 3. The maximum RMS strobe current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS <br /> current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying <br /> current waveform.) <br /> 85 <br /> E <br /> 83 <br /> O <br /> 82 <br /> 81 <br /> m 80 <br /> J <br /> ` 79 <br /> 7 <br /> y 78 <br /> mti <br /> IL 77 <br /> C <br /> e <br /> G 76 <br /> w <br /> 75 <br /> 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 <br /> Angular Displacement(Degrees)on Horizontal Axis <br /> -2kHz-4M <br /> 3 S4906-0003-4 512008 <br />