My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1178
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1178
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2022 8:06:22 AM
Creation date
6/1/2022 8:04:57 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM/SUNBELT INC
Building Department - Doc Type
Permit
Permit #
20-1178
Building Department - Name
ADVENTIST HEALTH SYSTEM/SUNBELT INC
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- 4009_IDNet NAC Extender,.-Continued <br /> 4,009 IDNet Configuration, Hardwired 4009 IDNet.Control <br /> continued <br /> There are two hardwired NAC control:inputs to the 4009.IDNet(when used as <br /> an IDNet device on.a 4010 these inputs are not used). The hardwired NAC. <br /> control inputs provide backward compatibility with.other Simplex panels-.1ii the <br /> hardwired mode,the 4009 IDNet is non-addressable and controlled via two DIP <br /> switches <br /> (Hard Configuration Switch SW1 and Software: <br /> Address/Configuration Switch SW2). Each input simulates a typical hardwired <br /> notification appliance,as seen from the host panel..When a fault occurs:on.the <br /> 4069 Addressable NAC system or on any of the outputs controlled by Input 1, <br /> the panel causes an open condition-on the host NAC that is connected to Input 1. <br /> Any faults on the outputs controlled by Input 2 are reflected on the host panel's <br /> NAC.in the same fashion..A power loss condition gat.the 4009 IDNet causes <br /> Input 1 to indicate a fault(open)condition: <br /> Inputs 1 and 2 can be configured either as EOL devices on the host NAC or as <br /> appliances on that NAC,,based on whether an.end-of-line load is presented to the <br /> host. Up to four 4009 IDNet NAC Extenders can be attached to the FACP(s) <br /> NAC. <br /> -Addressable 4009 IDNet'(IDNet Control) <br /> The 4009 IDNet is addressable when configured as an IDNet peripheral;this <br /> mode is also configured via DIP switches SWI and SW2. In the IDNet mode, <br /> SW2;(see Figure 5)sets.the address of the NACs connected to the 4009 IDNet <br /> which are.controlled and configured.by the 4010 FACP. The 4009 IDNet <br /> monitors each output NAC. If a trouble.occurs,faults(including NAC <br /> supervision,power,.battery integrity,and earth)are communicated to the host <br /> panel 4010 FACP as IDNet messages. <br /> 4009 IDNet BASE SYSTEM <br /> - <br /> (NO EXPANSION <br /> MODULES SHOWN) <br /> p <br /> TRANSFORMER <br /> t;? ASSEMBLY: <br /> SAFETY GROUNDib <br /> yy \{ •{ - BRIDGE RECTIFIER <br /> rVi <br /> �;�•u AC WIRING HARNESS <br /> sF?fin,4..s._. u• .... ..4, <br /> 91(120VAC4009)or <br /> _ �J 733 992,(22024 <br /> 4009 SYSTEM BOARD1 4009) <br /> ( <br /> 565-771(see Figure 4) <br /> f; • <br /> } 4 AC WIRING BLOCK <br /> -- <br /> z � • <br /> Figure 2. 4009 IDNet System Components <br /> Continued on next page <br /> 3 <br /> Technical Manuals Online! - htto://www.tech-man.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.