My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1187
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1187
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2022 8:14:24 AM
Creation date
6/1/2022 8:50:21 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-1187
Building Department - Name
LAEZZA,ANTHONY
Address
38039 7TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2020 Florida Building Code, Energy Conservation, 7th Edition <br /> Jurisdiction: 611600 Permit#: <br /> Jolbanformafiion,.. <br /> Builder: Community: Lot: NA <br /> Address: 38039 7th Ave <br /> City: Zephyrhills State: FL Zip: 33542 <br /> Air.Leakage Test ResU1tS "Passing iesults must meet either the Performance, Prescriptive; or ERI Method <br /> PRESCRIPTIVE METHOD--The building or dwelling unit shall be tested and verged as having an air leakage rate of riot exceeding 7 air <br /> changes peg hour at a pressure,of 0.2 inch w.g.(50 Pascals)in Climate Zones,1 and 2. <br /> O,_"P,ERFORMANCE"";or ERt METHOD The building or,dwell_Ing unit•shall be tested and"verified as having an air leakage rate of not exceeding <br /> the selected AC_H(5D)cvalve,as shown on Form R40!-202Q(Performance)or R406-2020(ERI);section"labeled as infiltration,.sub=section'ACH50: <br /> ACH(50)specrfieo`on Form R4Q5 2a20 EnergyCafp.(Performance)ar R406 2020(Eh'f): 6.000 <br /> x 60 _ 1386 = Method for calculating building volume: <br /> CFM(50) Building Volume ACH(50) O Retrieved from architectural plans <br /> ❑ PASS •Code software calculated <br /> When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(0, (g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration <br /> control measures. <br /> 2. Dampers including exhaust,intake,makeup air, back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. . <br /> 3. Interior doors,if installed at the time of the test,shall be open. <br /> 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> `Testitig:Corrtpany , ; .; . .. , .. • ; <br /> Company Name: Phone: <br /> I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code <br /> Energy Conservation requirements according to the compliance method selected above. <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 2/12/2021 9:03:46 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.