My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1187
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1187
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2022 8:14:24 AM
Creation date
6/1/2022 8:50:21 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-1187
Building Department - Name
LAEZZA,ANTHONY
Address
38039 7TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: Barker-38039 7th Ave <br /> lr••l^ 1C Date: Feb 05,2021 <br /> l l ltt s Entire House By: E-Calcs Plus,Inc. <br /> E-Calcs Plus, Inc. <br /> 9250 Corkscrew Rd,Suite 8,Estero,FL 33928 Phone:239.810.6106 Email:eric@ecalcsplus.com Web:www.ecalesplus.com License:HERS Rater ID 0757810 <br /> 'Project <br /> • • <br /> For: Barker-38039 7th Ave <br /> 38039 7th Ave,Zephyrhills, FL 33542 <br /> C001ih,g Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 16310 Btuh Entering coil DB: 76.3°F <br /> Outdoor design WB: 77.3°F Latent gain: 4640 Btuh Entering coil WB: 64.0°F <br /> Indoor design DB: 75.0°F Total gain: 20950 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHR <br /> Manufacturer: Carrier Model: 25HBC524AP0300+FX4DNF025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 18098 Btuh 111%of load <br /> Latent capacity: 4866 Bfuh 105%of load <br /> Total capacity: 22964 Btuh 1101/o of load SHR: 79% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.5°F Heat loss: 18464 Btuh Entering coil DB: 68.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524AP0300+FX4DNF025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 22471 Btuh 122%of load Capacity balance: 36 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -50 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Carrier Model: AFUE 100 <br /> Actual airflow: 800 cfm <br /> Output capacity: 5.0 ' kW 92%of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> wrtlgt tsoft 2021-Feb-12 09:01:39 <br /> Right-Suite®Universal 2021 21.0.03 RSU27537 Page 1 <br /> 39 7th Avell3arker-38039 7th Ave 2.12.2021.rup Calc=MJ8 Front Door faces:SE <br />