Laserfiche WebLink
FORM R405-2020 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: r-3803 7th Ave Builder Name:p(wa'G)✓1PAi`� r,�v'�,U <br /> Street: 38039 7th Ave Permit Office: Zelabgrhiffs c / v U <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: 11 6'7 <br /> Owner: Jurisdiction: 611600 <br /> Design Location: FL,Lakeland County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing Addition 10. Wall TypeV45.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Detached a.Frame-Wood,Exterior R=11.0 245.00 ftz <br /> b.N/A R= ft2 <br /> 3. Number of units,if multiple family 1 c. N/A R= p2 <br /> 4. Number of Bedroom�Bedrms In Addition) 0(0) d.N/A R= t2 <br /> 5. Is this a worst case? No 11.Ceiling Types (198.0 sqft.) Insulation Area a.Under Attic(Vented) R=19.0 198.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 198 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c. = ft2 <br /> 7. Windows(13.2 sqft.) Description Area 12. Ducts R ft2 <br /> a. U-Factor: Dbl,U=0.57 13.20 ft2 a.Sup:Attic, Ret:Attic,AH:Attic 6 15 <br /> SHGC: SHGC=0.24 <br /> b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 24.0 SEER:15.00 <br /> c. U-Factor_ N/A ft2 <br /> SHGC: 14. Heating systems kBtu/hr Efficiency <br /> Area Weighted Average Overhang Depth: 2.000 ft. <br /> Area Weighted Average SHGC: 0.240 a.Electric Heat Pump 24.0 HSPF:8.50 <br /> 8. Skylights Area <br /> c. U-Factor:(AVG) N/A ft2 15.Hot water systems-Replacement equipment <br /> SHGC(AVG): N/A a.Electric Cap:40 gallons <br /> 9. Floor Types (198.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 198.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 16.Credits Pstat <br /> Glass/Floor Area: 0.067 Total Proposed Modified Loads: 6.34 PASS <br /> Total Baseline Loads: 6.63 <br /> I hereby certify that the plans and specifications covered by Review of the plans and o 'Lfifi S7g <br /> this calculation are in compliance with the Florida Energy specifications covered by this 1+ +p <br /> Code. calculation indicates compliance ,,,��'''� <br /> with the Florida Energy Code. <br /> PREPARED BY: ' .._.._..............._.................. E_CalCs_P_I_t�6, IJ]c. Before construction is completed r <br /> DATE: February 12,..2021___.__.._._.__......_...............__._ this buildingwill be inspected for <br /> P <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes.. <br /> with the Florida Energy Code. COtj T�t� <br /> OWNER/AGENT: BUILDING O F �IAL: . <br /> DATE: DATE: ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. <br /> 2/12/2021 9:03 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 <br />