My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1188
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1188
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 2:40:08 PM
Creation date
6/1/2022 8:54:30 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1188
Building Department - Name
DR HORTON
Address
7254 STEER BLADE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br /> `. to <br /> • <br /> • <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered_ site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5; Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk=shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered.and marked at time of first inspection_ . <br /> 8: All A.D.A.requirements shall be met. <br /> 9-. No electric, plumbing, mechanical,or framing shall be covered without an inspection and <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.-C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors-are to be installed_ in accordance with R313.1 of the F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. `Green gypsum,board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance withthe F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit_. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.