My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1190
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1190
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 2:40:41 PM
Creation date
6/1/2022 8:57:19 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1190
Building Department - Name
DR HORTON
Address
7054 STEER BLADE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Camden 2795 Elev F,.,cw"'Multi Gen Builder Name: 11 Horton <br /> Street: S 1( ��ua,��t/ Permit Office: (;(' % r fV <br /> City,State,Zip: ephyrhills,FL, -6 ( Permit Number: /4c <br /> Owner: 7 ®. Jurisdiction: (0/1&ot> <br /> Design Location: FL,Tampa I 3 County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2331.8 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1956.90 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 374.89 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (3024.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 2836.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2836 b.Knee Wall(Vented) R=19.0 188.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11. Ducts R ft2 <br /> 7. Windows(330.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 529 <br /> a. U-Factor: Dbl,U=0.34 258.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 72.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 41.5 SEER:15.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.214 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (2836.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.116 <br /> Total Proposed Modified Loads: 84.99 PASS <br /> Total Baseline Loads: 87.48 <br /> I hereby certify that the plans and specifications covered by Review of the plans and EVE ST�g�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti�o Apt <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: ��11a Before construction is completed r '' <br /> DATE: 11-20-20 this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as desi ned,is in compliance Florida Statutes. <br /> with the Florida Energy Code. �. COI)yVE <br /> OWNER/AGENT: � BUILDING OFF'CIAL: <br /> DATE: DATE: ..ddAlt .14 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handier enc osure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier.and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. <br /> 11/20/2020 2:39 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.