` <br /> ` <br /> MANDATORY REQUIREMENTS ~ (Co|tinUm0 <br /> ��2.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to <br /> opencombustion fuel b ing appliances,the appliances d combustion airin <br /> enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements <br /> of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be <br /> fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403,The combustion air duct shall be insulated where it <br /> passes through conditioned space to a minimum of R-8. <br /> Exceptions: <br /> 1. Direct vent appliances with both intake and exhaust pipes installed continuous mthe outside. <br /> o. Fireplaces and stoves complying with Section R402.4.2 and Section R 1006 of the Florida Building Code,Residential. <br /> �lR4uu�.5 Recessed fighting. Recessed l i i installed i h building thermal envelope shall be sealed to limit air leakage <br /> between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not <br /> more than u.00hn(0.e44tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed <br /> luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. <br /> R4uo1 Controls. SECTION����� � R403 SYSTEMS <br /> n R403.1.1 Thermostat provision(Mondatpn0. At least one thermostat shall be provided for each separate heating and cooling system. <br /> �l 8oum�.mUa�pump supp|amao��»eo (Mandatory). He�pumps hav�guup�emen���nv�c~mu��ncahmgah� m�(havaoon� <br /> �� that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. <br /> �l R4ou.o.x Sealing Umandator0 All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways <br /> for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section <br /> C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. <br /> Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or <br /> (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in <br /> accordance with Section H«oo.a.o. <br /> �7 n403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent <br /> o,the design airflow rate when tested in accordance with AaHR4E1no. <br /> 84mm.o.3 Duct testing(mmndmory). Ducts shall be pressure tested to determine air leakage by one of the following methods: <br /> I Rough-in test:Total leakage shall bo measured with a pressure differential ofu.1 inch vug.(u5 Pa)across the system,including the <br /> manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. <br /> c. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch we(us Pa)across the <br /> entire system,including the manufacturer's air handler enclosure.Registers shall be taped or othenvise sealed during the <br /> test. <br /> Exceptions: <br /> 1. Aduct air leakage test shall not be required where the ducts and air handlers are located entirely within the building <br /> thermal envelope. <br /> u. Duct testing is not mandatory for buildings complying by Section«nam this code. <br /> A written report of the results of the test shall be signed by the party conducting the test and provided to the cocle-official. <br /> �� <br /> �� <br /> B4oV.3/xoui|dm0cavMmoyMoudatunN. Building framing cavities shall not bo used ao ducts mplenums. <br /> n403.4 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 1o5°F(41^C) <br /> or below a5~F(1o^C)shall ue insulated mo minimum ofR-o. <br /> �l e4n3.41 Protection o,piping insulation. Piping insulation exposed to weather shall be protected from damage,including that <br /> caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause <br /> degradation nf the material.Adhesive tape shall not bopermitted. <br /> �l o4uo.s� no�adna�rmnvu|ouon and�mpen�vmmoin�nanceova�mmVmaou�nnA' Heated water�mm�mnsvo�mosmmuem <br /> �� accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. <br /> Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. <br /> �l Rvuxm.1.1m|n,u|o�nnsystems. Heated w�o,cimui��nnymomoshall bopm�dodv�havimu|a�vn pump.The system onum <br /> �� pipe shall boa dedicated return pipe vra cold water supply pipe.Gravity and the,mmoiphun circulation systems shall uoprohibited. <br /> Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the <br /> occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and <br /> when there iono demand for hot water. <br /> R4mm.e.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE o1o.1 urULs1s.Controls for such systems <br /> shall automatically adjust the input to the heat tracing to maintain the desired water temperature in the piping inaccordance <br /> with the times when heated water is used in the occupancy. <br /> 11/20/20202:50PM EnergyoaugemuaA s000(nay. 1)'RaReuoo1rF8cnm Edition(on17) Compliant Software Page 2mu <br />