D <br /> Q <br /> r <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E..shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to.comply with R401:3 of the F.B.C. <br /> 3. Compaction test required if 24 or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways require.a R,O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All.property markers shall be uncovered.and.marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be met: <br /> R. No electric,.plumbing;mechanical, or framing shall.be covered without an inspection.and <br /> approval first: <br /> 10: All Garages shall comply with section R302:6 of the F.B.-C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to in an cal.damage unless <br /> protected by approved barriers. M303A of the F.B.0 <br /> 12. Water heaters-shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units:shall.be raised at least 3" above finished grade. M1308:1 <br /> 14:.Retuni air in all bedrooms. F.B:C. M1620.4 <br /> 1.5. Smoke detectors.are to be installed in accordance with R313.1 of.the.FAC. . <br /> 16: All lazing requirements are to be iri accordance with R3b8:4 of the F:B:C: <br /> g <br /> 17. All means of egress are to be-in accordance with R311 of-the F.B.C: <br /> 18. "Green.gypsum Board" shall not be used as a backer in showers or tubs. R702-4:2 F.B.C. <br /> 19._Combination-type AFCI breakers are required at all locations reguiririg an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground.plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />