Laserfiche WebLink
21 Tamper- Resistant Receptacles in accordance with 406.11 of-the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10. <br /> feet around the structure, <br /> 25.. R403.5.3Hot.water.pipe insulation. <br /> Insulation for_hot_water'pipe with a minimum-thermal resistance (R-value) of:R-3 shall.be applied to the <br /> following:; <br /> Piping.3/: inch (19.1 mm) and larger in-nominal diameter. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the.water heater to.a distribution manifold-. <br /> Piping.located under a floor slab: <br /> Buried in'-piping,= <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.BloWer_door test shall be provided before C.O; <br /> 26.A copy of the energy cacls shall be with permit at all times <br /> 27 Copy of final insulation reportslialhbe provided with permit before fnal <br /> 28. No fence,pool onscreen Enclosure :is-issued with:this permit= <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C--Florida Building Code 6t'Edition <br /> -R.O.W.-Right of Way. <br /> A.D.A.-.Americans with Disabilities Act. N.E.C.-National Electric Code(2016) <br />