Laserfiche WebLink
- - wrightsoft© <br /> Manual S Compliance Report Dab: <br /> Entire House By: <br /> Plan: Plan 2795 Camden <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton <br /> Lot 16 Blk 13 Silverado, Zephyrhills, FL <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 33375 Btuh Entering coil DB: 77.1OF <br /> Outdoor design WB: 77.1 OF Latent gain: 5252 Btuh Entering coil WB: 63.6°F <br /> Indoor design DB: 75.0°F Total gain: 38628 Btuh . <br /> Indoor RH: 50% Estimated airflow: 1383 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Bryant Model: 215BNA042+FX4DN(B,F)043 <br /> Actual airflow: 1383 cfm <br /> Sensible capacity: 33904 Btuh 102%of load <br /> Latent capacity: 5871 Btuh 112%of load <br /> Total capacity: 39775 Btuh 103%of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 32348 Btuh Entering coil DB: 69.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Bryant Model: 215BNA042+FX4DN(B,F)043 <br /> Actual airflow: 1383 cfm <br /> Output capacity: 37812 Btuh 117%of load Capacity balance: 33 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1383 cfm <br /> Output capacity: 9.6 kW 102%of load Temp. rise: 22 OF <br /> Meets are all requirements of ACCA Manual S. <br /> 1 htsoft' <br /> wri <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 2020-Nov-2014:45:33...tsoft Files\SF Tampa\2795 w Multi gen suite.rup Calc=MJ8 House Front faces: W Page 1 <br />