Laserfiche WebLink
r. <br /> D <br /> I i <br /> L- <br /> I <br /> * is <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.comply with R401.3 of the F.B.C.- <br /> Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before,pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: All 4 sides of driveway thm the sidewalk shall have <br /> expansion material.. <br /> 6. All setbacks shall be met. <br /> T All property markers shall be uncovered and.maeked at time of first inspection. <br /> & All A.D.A.requirements shall be met: <br /> 9; No electric,plumbing, mechanical, or framing shall be:covered without an inspection and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F:B.0 <br /> 12. Water heaters'.shall comply with section P607.3 ofthe F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3"-above finished grade. M1308:1- <br /> 14: Return air in all bedrooms. F.B:C. M1620A <br /> 1.5. Smoke detectors are to be installed in accordance with R313:1 of-the F.B.C. <br /> 16. All glazing requirements are to be i - accordance with R308:4 of the F.B.C; <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C. <br /> 18. `-`Green gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring aFCI n A type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />