20-1196
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1196
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 2:41:45 PM
Creation date
6/1/2022 9:02:11 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1196
Building Department - Name
DR HORTON
Address
7864 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 22, BLOCK 8, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 28, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA., <br /> Pc LOT 21 <br /> I BLOCK 8 <br /> I ►�� S89'25'08"E 1'14.53 * e <br /> W3 <br /> r IzFw -- i -- m m z <br /> 27.0' O7, a 1" - 30' <br /> w I b w GRAPHIC SCALE <br /> 3 ml�rc I COVERED < N 4f w C�a 0 15 30 <br /> o I ENTRY <br /> N <br /> p• KT5 I io I 4.0'~ 4EVB DAKO�TAD'A' S o ;:t? b N U c N <br /> a FINISHED FLOOR .°� r _4.. o ~ OI m U <br /> co ELEVATION-89.70' J N Q <br /> M. <br /> ;..r. N <br /> 4887 <br /> s, <br /> 0 W <br /> Q WD m -- I27.D'— -----38.9- --- o Q <br /> 5'D&AE m <br /> °° g N625.00'—W s, N89'25'08"W 1114.60'0 <br /> e0► <br /> ICd I LOT 23 <br /> BLOCK 8 <br /> PIi <br /> ON LOT CALCULATIONS <br /> LOT = 5,728 SQ. FT. <br /> LIVING AREA = 1,402 SO. FT. <br /> GARAGE = 424 SO. FT. <br /> ENTRY = 16 SQ. FT. <br /> LANAI = 0 SO. FT. <br /> PATIO = 80 SO. FT. <br /> DRIVEWAY = 432 SO. FT. <br /> A/C PAD = 12 SO. FT. <br /> WALKWAY - 27 SO. Fr. <br /> PREPARED FOR: IMPERVIOUS = 42% <br /> = 2393 SQ. FT. <br /> ��g�ryry x*TT + SOD - 3,335 SO. FT. <br /> OFF LOT CALCULATIONS <br /> iitGs'1CR�5 RIGHT OF WAY = 650 SO. FT. <br /> BUILDING SETBACKS PUBLICAS/WN = 50 SQ. FT. <br /> FRONT: 22' SOD = 248 SO. FT. <br /> GARAGE: 27' TOTALS <br /> REAR: 13' AREA = 6,378 SQ. FT. <br /> SDE: 5' DRIVEWAY = 584 SQ. FT. <br /> SIDE STREET: 15' SIDEWALK = 277 SO. FT. <br /> SOD = 3.583 SQ. FT. <br /> NOTES: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE <br /> BASED ON THE APPROVED ENGINEERING PLANS <br /> PREPARED BY HAMILTON ENGINEERING dK LEGEND: <br /> SURVEYING INC.. <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 —•—•— BUILDING SETBACK UNE PI POINT OF INTERSECTION <br /> DATUM. PC POINT OF CURVATURE <br /> 3. FOR ALL LOTS WHERE SIDE-YARD —-— CENTERUNE PT POINT OF TANGENCY <br /> RIGHT OF WAY LINE RP RADIUS POINT <br /> SETBACKS ARE LESS THAN 7.50 FEET, A —-- PRC POINT OF REVERSE CURVATURE <br /> MINIMUM 5.00 FOOT WIDE DRAINAGE AND PROPOSED ELEVATION PTT�P PERMANENT CONTROL POINT <br /> ACCESS EASEMENT IS REQUIRED PER PASCO <br /> COUNTY LAND DEVELOPMENT CODE. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> "v (P) PER PLAT <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (C) CALCULATED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER pa PAS GOK <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR S/W SIDEWALK SO.FT, SQUARE FEET <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING (A) PER AFFIDAVIT F.EM.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.I.R.M. FLOOD INSURANCE RATE MAP <br /> CONSTRUCTION. DAVID&AAE DRAINAGE&&ACCEAN SS EASEMENTICAL T <br /> DE DRAINAGE EASEMENT(PUBLIC) <br /> THIS IS NOT A SURVEY UE UTILITY EASEMENT(PUBLIC) <br /> THIS IS A PLOT PLAN ONLY W&LE WALL.&.LANDSCAPE EASENT(PRIVATE) <br /> FLOOD NOTE: SURVEYOR NOTES: <br /> I HAVE EXAMINED THE F.I.R.M.MAP NO. 1210100293F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> DATED 09/26/2014,AND FOUND THE SUBJECT PROPERTY APPEARS TO LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> LIE IN ZONE X' AREAS DETERMINED TO BE OUTSIDE THE 0.2X ANNUAL OF WAY, RESTRICTIONS OF RECORD WHICH <br /> 05--1 FIAODPWN PER LOMR CASE N0.GUARANTEES <br /> DATED MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> INFORMATION.PIPAA CONTACT LOCALAFEM�AGGEENTOFOR ABOVE <br /> VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF BROAD A5hA 3. NOT VALID WITHOUT THE AUTHENTIC <br /> POINTE DRIVE BONG NOO'34'52-E,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> ELECTRONIC SEAL OF A FLORIDA LICENSED <br /> REVISED: A M E FR 1 CAN SURVEYOR AND MAPPER. <br /> (FIELD DATE:) S U RV IE Y I N G <br /> w'omamma Digitally signed bylames W Boleman <br /> SCALE: 1� FAT :..".v eon DN:c=US,st=FIorida,l�dando, <br /> SL MAPPING I N C. % o=AMEBICAN SURVEYING& <br /> APPROVED BY. JB �w, Bolemnl G,INC,cn=James W <br /> CERTIFICATION OF AUTHORIZATION NUMBER LB/6393 r; "— <br /> 3191 MAGUIRE BOULEVARD, SUITE 200 . .r" emali=lboleman@asmmrporate.com FOR <br /> 190901 LOT 22, BLOCK B C,,,;:;•, Date:202o.10.1e10-aa13-04'en THE <br /> JOB NO. ORLANDO, FLORIDA 321303 cv®,®m�` ,° Adobe Acrobat version:11.023 FIRM <br /> (407) 426-7979 <br /> DRAWN BY; DSB PLOT PLAN 10 5 2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE <br />