My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1197
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1197
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 2:41:56 PM
Creation date
6/1/2022 9:02:52 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1197
Building Department - Name
DR HORTON
Address
7918 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E;.shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.comply with R401-3 of the F.B.C. <br /> 3. Compaction test required if 24".or more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 1. All piroperfy markers shall be uncovered,and marked at time of first inspection. <br /> 8:- All A.D.A.requirements shall be met: <br /> 9: 'No electric,plumbing,.mechanical, or framing shall be_covered without an:inspection and <br /> approval first: <br /> 10: All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation).. <br /> . <br /> 11. Appliances shall not be installed in a location where'subiect to mechanical damage unless <br /> protected by'approved barriers. M303;4 of the F.B.0 <br /> 12. Waterheaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above f nislied grade. M1308:1 <br /> 14: Return air in all bedrooms, F.B.C. M1620:4 <br /> 15. Smoke detectors are to be- installed in accordance with R313:1 of the F.B.C. <br /> 16.All glazing requirement s are to be in accordance with R308A of the F.B.C. <br /> 17. All means.of egress are to be in accordance'with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. . <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker-. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground,plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.