Laserfiche WebLink
23. Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be-sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation. <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> followin <br /> 9:. <br /> Piping 31,inch (19.1 mm)and larger.in nominal diameter. <br /> Piping serving more than:one dwelling unit: <br /> Piping located outside the conditioned space:_ <br /> Piping from the water heater to a distribution manifold. <br /> Piping located under a floor slab.- <br /> Buriied in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower.door test shall be provided before C.O. <br /> 26.A copy of the enerzy:cacls shall be ivith permit at all times <br /> 2z Copt/of inatinsulation report shall be provided with permit before fnaL <br /> 28.No fence,pool or screen enclosure :is issued with:this.permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C--Florida Building Code 6'Edition <br /> R.O.W.-Right of Way - <br /> A.D.A.-Americans with Disabilities Act: N.E.C.-National Electric Code(2016) . <br />