My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1218
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1218
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2022 12:54:18 PM
Creation date
6/1/2022 9:12:27 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-1218
Building Department - Name
CARIERA,JOSETTE
Address
37756 NEUKOM AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Test Report No.: F6892.02-401-44 <br /> Report Date: 06/27/16 <br /> Architectural Testing Page 6 of 8 <br /> 7.0 Test Results: The temperature during testing was 260C(79eF). The results are tabulated as <br /> follows: <br /> Title of Test Results Allowed Note <br /> Air Leakage, - - <br /> per ASTM E283 0.1 L/s/mZ 5.0 L/s/m2 <br /> at 75 Pa (1.57 psf) (0.02 cfm/ft2) (1.0 cfm/ft2)max. <br /> Water Penetration, <br /> per ASTM E 547 <br /> at 000 Pa(0.00 psf) Pass No leakage 1 <br /> Uniform Load Deflection, <br /> per ASTM E330 <br /> Deflections taken at lock stile <br /> +1197,Pa (+25.00 psf) 1.8 mm (0.07") <br /> -1197 Pa (-25.00 psf) 1.0 mm (0.04") Report Only 2, 3 <br /> Uniform Load Deflection, <br /> per ASTM E330 <br /> Deflections taken at hinge stile <br /> +1197 Pa (+25.00 psf) 0.8 mm (0.03") <br /> -1197 Pa (-25.00 psf) 1.0 mm (0.04") Report Only 2,3 <br /> Uniform Load Structural, <br /> per ASTM E330 <br /> Permanent sets taken at <br /> lock stile <br /> +1795 Pa (+37.50 psf) 0.3 mm(0.01") <br /> -1795 Pa (-37.50 psf) 0.3 mm(0,01") Report Only 2,3 <br /> Uniform Load Structural, <br /> per ASTM E330 <br /> Permanent sets taken at <br /> hinge stile <br /> +1795 Pa(+37.50 psf) 0.3 mm(0.01") <br /> -1795 Pa(-37.50 psf) 0.3 mm(0.01") Report Only 2, 3 <br /> General Note: All testing was performed in accordance with the referenced standard(s). <br /> Note 1: Without insect screen. <br /> Note 2: Loads were held for 10 seconds. <br /> Note 3: Tape and film were used to seal against air leakage during structural testing. In <br /> our opinion, the tape and film did not influence the results of the test. <br /> wvvw.archtest.com . www.intertek.corNbuilding <br />
The URL can be used to link to this page
Your browser does not support the video tag.