Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 <br /> 24. In accordance with-the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water.pipe insulation. <br /> Insulation for hot water'pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping�1. inch (1.9.1 mm) and larger,in nominal diameter.- <br /> Piping,serving more-than one dwelling unit. <br /> Piping located outside the conditioned space... <br /> Piping from the water heater to a distribution manifold-, <br /> Piping:located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower-door test shall be provided before C.O: <br /> 26.A copy of the-energy cacls shall be with uerniit at all times: <br /> 27. Copy of final.insulation report-shall-A?provided ivith permit before final <br /> 28. No'fence, pool onscreen enclosure':is issued with:this.permit <br /> F.F.E.-Finished Floor Elevation <br /> RB.C-...Florida Building Code 6ffi Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />