Laserfiche WebLink
Q <br /> ft <br /> Single Family. Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.-B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.M. use permit_: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6. All setbacks shall be met. <br /> 7-. All property markers shall be uncovered.and marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be met. <br /> 9-. No electric,plumbing;mechanical, or framing shall be:covered without an inspection.and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where-subject.to mechanical damage unless <br /> - protected byapproved barriers. M303:4 of the F B.0 <br /> 12.'Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. MONA .. <br /> 14. Return air in all bedrooms. F.B.C. M162.OA <br /> 1.5. Smoke detectors are to be installed in-accordance with.R313.1 of the F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R3I I of the F.B.C. <br /> 18. `-`Green gypsum board" shall not be used as a backer-in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AM breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit.to unit. This includes all <br /> underground.plumbing and electric. <br /> 22. All 2016. ME.C. Codes will be enforced. <br />