Laserfiche WebLink
23..Tamper- Resistant Receptacles in accordance with 406.11 ofthe, 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots:shall.be sodded before final at least 10 <br /> feet around the structure: <br /> 25:.R403.5.3Hof.Water_pipe insulation <br /> insulation for hot.water. pipe'with.a minimum thermal resistance (R.value) of R-3 shall be applied.to the <br /> follow' In <br /> Piping-3/: inch (19.1 mm)and larger in:nominal diameter. <br /> Piping,serving more than one dwelling unit. <br /> Piping located outside the conciition.ed space: <br /> Piping from the:Water heater to a'distribution manifold:, <br /> Piping:located under,a floor slab: <br /> Buried in-piping. <br /> Supply and return piping in recirculation'systems other than demand recirculation systems. <br /> 25: Blower.door test shall be provided.bef0e' C-.O: . <br /> 26.A cony of the energy eacls shall be with permit at all times <br /> 27. Cony of final-insulation report shall be provided with Permit before rinaL <br /> 28. No fence,pool or screen enclosure is issued-with:this permit: <br /> RRE.-Finished Floor Elevation . <br /> RB.C=•Florida Building Code 61h Edition <br /> R.O.W'-Right of Way <br /> A.D:A.=Americans with Disabilities Act:. N.E.C.-National Electric Code (2016) <br />