Laserfiche WebLink
ti <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> .24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25:.R403.5.3Hot water pipe insulation. <br /> Insulation for hot Water.'pipe with'a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping V. inch (1.9.1 mm)and larger in nominal diameter. <br /> Piping serving more than:one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the:Water heater-to a distribution manifold. <br /> Piping located under a flOOr slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation'systems other than demand recirculation systems. <br /> 25. Blower door-test shall be provided before C.O. . <br /> 26.A cope of the energy cacls shall be with permit at all times <br /> 2Z. Copy of final insulationz redortshall be provided with permit before final <br /> 28. No fence, pool or-screen enclosure is-issued.with:this.permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6ffi Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />