Laserfiche WebLink
_ F � <br /> t: <br /> a <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F."RE; shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to.comply with R401:3 of the F.B.C. . <br /> 3: Compaction test required if 2. or more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit_. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All property markers shall be uncovered.and marked at time of first inspection. <br /> 8: All A.D:.A. requirements shall.be met:. <br /> -9: No electric,.plumbing; mechanical, or framing shall.be:covered without an inspection.and <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).' <br /> 11. Appliances shall not be installed in a-location where subject to mechanical:damage unless <br /> protected by approved barriers. 1VI303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13: Foundation supports for A/C units shall b:e raised at least 3" above-finished grade. M1308.:1 . <br /> 14. Return air in all bedrooms. F.B:C.- M1620:4 <br /> 15. Smoke detectors are to be installed in accordance with R3111 of.the F.B.C. <br /> 16. All glazing reguiremeiits are to be:in accordanee.with R308.4 of the RB.C: <br /> 17: All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as,a backer in showers or tubs.R702:4.2 F.B.C'. <br /> 19: Combination-type AFCI,breakers are required at all-locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be"separate:from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22: All 2016 N.E.C. Codes will be enforced. <br />