Laserfiche WebLink
4" MAX. MIN.DISTANCE STEEL INSTALLATION <br /> FROM FOR EDGE:1/2" <br /> Min.embedment <br /> —r CORNERS �of three Threads <br /> 2 3 past frame ' <br /> 1 b <br /> 18 gauge min 18 gauge mitt <br /> �MIDSPAN <br /> 16 1/2" � 1/4"MAX Steel Stud Steel Stud <br /> O.C. MAX. SHIM SPACE 1/4"MAX <br /> 3 SHIM SPACE <br /> MIN.DISTANCE <br /> FRAME SECTION(TYP) FOR EDGE:1/2" <br /> VERTICAL SECTION <br /> Min.embedment <br /> of three threads 2 <br /> past frame <br /> i <br /> 1 <br /> JAMB SECTION(TYP) <br /> O HORIZONTAL SECTION <br /> U <br /> 1 D 1/4"MAX <br /> SHIM SPACE <br /> O <br /> 38 gauge min <br /> Steel Stud <br /> 3 Max Frame DP RATING IMPACT <br /> 48 x 77 +50/-50 1 NO <br /> Installation Notes: General Notes: <br /> 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria <br /> 2. For anchoring into metal framing,use#8 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida <br /> minimum embedment of three threads past the frame thickness. Locate anchors as shown in Building Code(FBC)and the industry requirement for the stated conditions. <br /> elevations and installation details. Steel substrate min.18ga.,fy=33 ksi. 2. All glazing shall conform to ASTM E1300. <br /> 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing shall be single strength annealed insulating glass. <br /> to the structure. The host structure is the responsibility of the architect or engineer of record for the <br /> project of installation. <br /> `,,,Illllllf///�'' <br /> This schedule addresses only the fasteners required to anchor the `�� �S F. <br /> window to achieve the rated design pressure up to the size limitations �� . �,.:. ., <br /> noted. It is not intended as a guide to the installation process and does �� PRO]ECr ENGINEER: DATE: 3737 Lakeport Blvd <br /> not address the sealing consideration that may arise in different wall '�; . •: O -- 03/31/2017 JELDrWENK[amath Falls,OR.97601 <br /> conditions. For the complete installation procedure,see the instructions _ * ,' 7 DRAWN BY: SCALE:';*, _ 3,HAWKINS NTS Phone: (541)882-3451 <br /> packaged with the window or go to www.jeld-wen.com. <br /> � • T T ; .� CHECKED BY: TITLE: <br /> 44, D.BELAU <br /> w�O '• ( pP;� 407 APPROVED BY: Builders Vinyl Tilt Single Hung <br /> DISCLAIMER: �� '� �_ .�� ].GOOSSEN <br /> This drawing and its contents are confidential and are not to be �� ' \0 �� PART PRO ECT o <br /> reproduced or copied in whole or in part or used or disclosed to others �➢©� �� <br /> D604�� <br />