Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance'with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation. <br /> Insulation for.hot water pipe With a minimum thermal resistance (-R-value) of R-3 shall.be applied to the <br /> following: <br /> Piping 31; inch (1.9.1 mm) and larger in nominal diameter._ <br /> Piping serving more than one dwelling unit. <br /> Piping located outside'the conditioned space. <br /> Piping from the W;titer heater to a distribution manifold: <br /> Piping located under,a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation-systems. <br /> 25. Blower.door'test shall be provided.before C.O: <br /> 26.A copy of the energy cacls shall be.with werniit at all times <br /> 27. Copy offnal insulation-report shall be provided with permit before fnah <br /> 28.1 No fence, pool or screen'enclosure Is issued with:this-permit <br /> RRE,Finished Floor Elevation <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />