dn-7114:c•Al-65 <br /> N-ANN-80 <br /> NOT 1 F'1 E R <br /> so-Character LCD <br /> Serial Annunciator by Honeywell <br /> Annunciators <br /> General <br /> The N-ANN-80 annunciator is a compact, backlit, 80-character <br /> LCD fire annunciator that mimics the Fire Alarm Control Panel <br /> (FACP) display. It provides system status indicators for AC <br /> Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- <br /> tions. The N-ANN-80 and the FACP communicate over a two- <br /> wire serial interface employing the ANN-BUS communication <br /> format. Connected devices are powered, via two additional <br /> wires, by either the host FACP or a remote UL-listed, filtered <br /> power supply. N-ANN-80 is black;for white order N-ANN-80-W. <br /> The N-ANN-80 displays English-language text of system point N <br /> �j NOTIFIER <br /> information including device type, zone, independent point I ,.,T E byH°nay weIII <br /> alarm, trouble or supervisory status, as well as any custom <br /> alpha labels programmed into the control panel. It includes con- <br /> trol switches for remote control of critical system functions. (A s <br /> keyswitch prevents unauthorized operation of the control <br /> switches.) <br /> Up to eight N-ANN-80s may be connected to the ANN-BUS of <br /> each FACP. Minimal programming is required,which saves time <br /> during system commissioning. The N-ANN-80 is compatible <br /> with NOTIFIER FACPs with an ANN-BUS,such as the NFW-50. <br /> Features • Trouble <br /> • Supervisory <br /> • Listed to UL Standard 864,9th Edition. • Alarm Silenced <br /> • Backlit 80-character LCD display(20 characters x 4 lines). <br /> • Mimics all display information from the host panel. Specifications <br /> • Control switches for System Acknowledge, Signal Silence, . Operating voltage range: 18 VDC to 28 VDC. <br /> Drill,and Reset. ' <br /> • Control switches can be independently enabled or disabled ' Current consumption @ 24 VDC nominal(filtered and non- <br /> at the FACP.• <br /> 40 mA maximum. <br /> • Keyswitch enables/disables control switches and mechani- ' Ambient temperature:32°F to 120°F(0°C to 49°C). <br /> cally locks annunciator enclosure • Relative humidity: 93%±2% RH (noncondensing) at 32°C <br /> • Keyswitch can be enabled or disabled at the FACP. <br /> ±2°C(90°F±3°F). <br /> • Enclosure supervised for tamper. • 5.375" (13.65 cm.) high x 6.875' (17.46 cm.) wide x 1.375" <br /> (3.49 cm.)deep. <br /> • System status LEDs for AC Power,Alarm,Trouble, Supervi- For use indoors in a dry location. <br /> • Local sounder can be enabled or disabled at the FACP. <br /> so and Alarm Silence. All connections are power-limited and supervised. <br /> • N-ANN-80 connects to the ANN-BUS terminal on the FACP Agency Listings and Approvals <br /> and requires minimal panel programming. <br /> • Displays device type identifiers, individual point alarm, trou- The listings and approvals below apply to the N-ANN-80. In <br /> ble,supervisory,zone,and custom alpha labels. some cases, certain modules may not be listed by certain <br /> • Time-and date display field. approval agencies,or listing may be in process. Consult factory <br /> • Surface mount directly to wall or to single, double, or 4" for latest listing status. <br /> square electrical box. • UL:S635 <br /> • Semi-flush mount to single, double, or 4' square electrical • FM approved <br /> box.Use ANN-SB80KIT for angled view mounting. • CSFM:7120-0028:240 <br /> • Can be remotely located up to 6,000 feet(1,800 m)from the • MEA:442-06-E Vol.2 <br /> panel. <br /> • Backlight turns off during AC loss to conserve battery power The ANN-BUS <br /> but will turn back on if an alarm condition occurs. <br /> • May be powered by 24 VDC from the host FACP or by remote POWERING THE DEVICES ON THE ANN-BUS FROM <br /> power supply(requires 24 VDC). AUXILIARY POWER SUPPLY <br /> • Up to eight N-ANN-80s can be connected on the ANN-BUS. The ANN-BUS can be powered by an auxiliary power supply <br /> when the maximum number of ANN-BUS devices exceeds the <br /> Controls and Indicators ANN-BUS power requirements. See the FACP manual for more <br /> • AC Power information. <br /> • Alarm <br /> dn-7114:c•5/22/09—Page 1 of 2 <br />