My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1261
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1261
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2022 8:17:27 AM
Creation date
6/1/2022 9:44:17 AM
Metadata
Fields
Template:
Building Department
Company Name
COPELAND FAITH PARTNERS LLC
Building Department - Doc Type
Permit
Permit #
20-1261
Building Department - Name
COPELAND FAITH PARTNERS LLC
Address
3752 COOPELAND DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN-6927:A2 <br /> FOPS.24S6(C/E) & FCPS. <br /> 2458(C/E) AJ N QT 1 F 1 E R® <br /> 6- & 8-Amp 24-Volt by Honeywell <br /> Remote Power Supplies <br /> Power <br /> General <br /> The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are <br /> remote power supplies with battery charger.The FCPS-24S6/- <br /> 2458 may be connected to any 12 or 24 volt fire alarm control . . <br /> panel (FACP) or may be used as stand-alone supplies. Pri- <br /> mary applications include notification appliance circuit (NAC) <br /> expansion (to support ADA requirements and NAC synchroni- <br /> zation) or auxiliary power to support 24 volt system accesso- <br /> ries.The FCPS-24S6/-2458 provides regulated and filtered 24 <br /> VDC power to four notification appliance circuits configured as <br /> either four Class B (Style Y)or Class A(Style Z,with ZNAC-4 <br /> option module). Alternately, the four outputs may be config- <br /> ured as all non-resettable, all resettable or two non-resettable -- <br /> and two resettable. The FCPS-24S6/-24S8 also contains-a ( _ <br /> battery charger capable of charging up to 18 AH batteries. <br /> FCPS-24S6C&FCPS-24S8C are ULC-listed. <br /> NOTE. Unless otherwise specified, the terms FCPS-24S6 and <br /> FCPS-24S8 used in this document refers to the standard FCPS- <br /> 2456 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the <br /> FCPS-24S6E and FCPS-24SBE <br /> Features <br /> • UL-Listed NAC synchronization using System Sensor, • Includes integral battery charger capable of charging up to <br /> Wheelock,or Gentex"Commander2"appliances. 18 AH batteries. Cabinet capable of housing 7.0 AH batter- <br /> • Operates as a "sync-follower" or as a "sync-generator" ies. <br /> (default). See note on page 2. • Battery charger may be disabled via DIP switch for applica- <br /> • Contains two fully-isolated input/control circuits -triggered tions requiring larger batteries. <br /> from FACP NAC (NAC expander mode) or jumped perma- • Fixed, clamp-type terminal blocks accommodate up to 12 <br /> nently"ON"(stand-alone mode). AWG(3.1 mm2)wire. <br /> • Four Class B (Style Y) or four Class A (Style Z, with <br /> ZNAC-4 module)NACs. Specifications <br /> • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- Primary(AC)Power: <br /> put, with 3 amps maximum/circuit, in NAC expander mode <br /> (UL 864). • FCPS-24S6C/-24S8C: 120 VAC,60 Hz,3.2A maximum. <br /> • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. <br /> output in stand-alone mode(UL 1481). • Wire Size: minimum#14 AWG(2.Omm2)with 600 V insula- <br /> • Compatible with coded inputs;signals passed through. tion. <br /> • Optional power-supervision relay(EOLR-1). Control Input Circuit: <br /> • In stand-alone mode, output power circuits may be config- • Trigger Input Voltage: 9 to 32 VDC. <br /> ured as: resettable, (reset line from FACP required), • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 <br /> non-resettable,or a mix of two and two. -16 V). <br /> • Fully regulated and filtered power output-optimal for pow- Trouble Contact Rating: 5 A at 24 VDC. <br /> ering four-wire smoke detectors, annunciators, and other Auxiliary Power Output: Specific application power 500 mA <br /> system peripherals requiring regulated/filtered power. maximum. <br /> • Power-limiting technology meets UL power-limiting require- <br /> ments. Output Circuits: <br /> • Form-C normally-closed trouble relay. • +24 VDC filtered,regulated. <br /> • Fully supervised power supply,battery,and NACs. • 3.0 A maximum for any one circuit. <br /> • Selectable earth fault detection. • Total continuous current for all outputs(stand-alone mode): <br /> • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S6: 4.0 A maximum. <br /> • Works with virtually any UL 864 fire alarm control which uti- —FCPS-24S8: 6.0 A maximum. <br /> lizes an industry-standard reverse-polarity notification cir- • Total short-term current for all outputs(NAC expander mode): <br /> cuit(including unfiltered and unregulated NAC power). —FCPS-24S6: 6.0 A maximum. <br /> • Requires input trigger voltage of 9-32 VDC. —FCPS-24S8: 8.0 A maximum. <br /> • Self-contained in compact, locking cabinet-15"H x 14.5"W Secondary Power(Battery)Charging Circuit: <br /> x 2.75"D(cm:38.1 H x 36.83W x 6.985D). <br /> • Supports lead-acid batteries only. <br /> DN-6927:A2.5/17/13—Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.