DN-6726:D•H-240 <br /> NBG-12LX N OTI F 1 E R° <br /> Addressable Manual Pull Station <br /> by Honeywell <br /> General <br /> The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., j <br /> requires two motions to activate the station) pull station that <br /> includes an addressable interface for any Notifier intelligent <br /> control panel except FireWarden series panels, and the NSP- <br /> 25 panel. Because the NBG-12LX is addressable, the control <br /> panel can display the exact location of the activated manual l <br /> station. This leads fire personnel quickly to the location of the <br /> alarm. <br /> 1 <br /> Features <br /> • Maintenance personnel can open station for inspection and <br /> address setting without causing an alarm condition. <br /> • Built-in bicolor LED, which is visible through the handle of �n <br /> the station, flashes in normal operation and latches steady I' <br /> red when in alarm. <br /> • Handle latches in down position and the word"ACTIVATED" <br /> appears to clearly indicate the station has been operated. <br /> • Captive screw terminals wire-ready for easy connection to <br /> SLC loop(accepts up to 12 AWG/3.25 mm2 wire). The NBG-12LX <br /> • Can be surface mounted (with SB-10 or SB-1/0) or semi- Addressable Manual Pull Station <br /> flush mounted. Semi-flush mount to a standard single- Installation <br /> gang,double-gang,or 4"(10.16 cm)square electrical box. <br /> • Smooth dual-action design. The NBG-12LX will mount semi-flush into a single-gang, dou- <br /> • Meets ADAAG controls and operating mechanisms guide- ble-gang, or standard 4" (10.16 cm) square electrical outlet <br /> lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. box, or will surface mount to the model SB-10 or SB-1/0 sur- <br /> maximum activation force. face backbox. If the NBG-12LX is being semi-flush mounted, <br /> • <br /> Highly visible. then the optional trim ring (BG12TR) may be used. The <br /> BG12TR is usually needed for semi-flush mounting with 4" <br /> • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). <br /> • Key reset. <br /> • Includes Braille text on station handle. Operation <br /> • Optional trim ring(BG12TR). Pushing in, then pulling down on the handle causes it to latch <br /> • Meets UL 38, Standard for Manually Actuated Signaling in the down/activated position. Once latched,the word"ACTI- <br /> Boxes. VATED" (in bright yellow) appears at the top of the handle, <br /> • Up to 99 NBG-12LX stations per loop on CLIP protocol while a portion of the handle protrudes from the bottom of the <br /> loops. station. To reset the station, simply unlock the station with the <br /> e <br /> Up to 159 NBG-12LX stations per loop on FlashScan@ pro- key and pull the door open.This action resets the handle;clos- <br /> tocol loops. ing the door automatically resets the switch. <br /> • Dual-color LED blinks green to indicate normal on Each manual station, on command from the control panel, <br /> FlashScan@ systems. sends data to the panel representing the state of the manual <br /> switch.Two rotary decimal switches allow address settings <br /> Construction (1 —159 on FlashScan@ systems, 1 —99 on CLIP systems). <br /> Shell, door, and handle are molded of durable polycarbonate Architectural/Engineering <br /> material with a textured finish. Specifications <br /> Specifications Manual Fire Alarm Stations shall be non-coded, with a key- <br /> operated reset lock in order that they may be tested, and so <br /> • Shipping Weight: 9.6 oz. (272.15 g) designed that after actual Emergency Operation, they cannot <br /> • Normal operating voltage:24 VDC. be restored to normal except by use of a key.An operated sta- <br /> • Maximum SLC loop voltage:28.0 VDC. tion shall automatically condition itself so as to be visually <br /> detected as activated. Manual stations shall be constructed of <br /> • Maximum SLC standby current:375 pA. red-colored polycarbonate material with clearly visible operat- <br /> • Maximum SLC alarm current: 5 mA. ing instructions provided on the cover. The word FIRE shall <br /> • Temperature Range:32°F to 120°F(0°C to 49°C) appear on the front of the stations in white letters, 1.00 inches <br /> • Relative Humidity: 10%to 93%(noncondensing) (2.54 cm) or larger. Stations shall be suitable for surface <br /> mounting on matching backbox SB-10 or SB-I/O;or semi-flush <br /> • For use indoors in a dry location mounting on a standard single-gang, double-gang, or <br /> DN-6726:D•4/13/2012—Page 1 of 2 <br />