My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1261
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1261
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2022 8:17:27 AM
Creation date
6/1/2022 9:44:17 AM
Metadata
Fields
Template:
Building Department
Company Name
COPELAND FAITH PARTNERS LLC
Building Department - Doc Type
Permit
Permit #
20-1261
Building Department - Name
COPELAND FAITH PARTNERS LLC
Address
3752 COOPELAND DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN-60977:A <br /> FSP-951 Series NOTIFIER 0 <br /> Intelligent Plug-In Photoelectric <br /> Smoke Detectors by Honeywell <br /> Devices <br /> The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors <br /> are designed for both performance and aesthetics. A new modern, <br /> sleek,contemporary design and enhanced optical sensing chamber - <br /> is engineered to sense smoke produced by a wide range of combus- <br /> tion sources in accordance with more stringent code standards.The / <br /> FSP-951 Series detector sensitivity can be programmed in the con- <br /> trol panel software. Sensitivity is continuously monitored and <br /> reported to the panel. Point ID capability allows each detector's f <br /> address to be set with rotary, decimal address switches, providing <br /> exact detector location for selective maintenance when chamber <br /> contamination reaches an unacceptable level. Dual electronic <br /> thermistors add 135°F(57°C)fixed temperature thermal sensing on <br /> the FSP-951T.The FSP-951 R is a remote test capable detector for <br /> use with DNR Series duct detector housings. FSP-951 series detec- <br /> tors are available for both FlashScan® and CLIP applications as <br /> designated. <br /> Features <br /> • New modern profile for improved aesthetics. <br /> • Designed to meet UL268 7th Edition. FSP-951 in B300-6 Base <br /> • Stable communication technique with noise immunity. <br /> • Low standby current. <br /> • Two-wire SLC connection. FSP-951 R installed in a DNR/DNRW, -20°C to 70°C (-4°F to <br /> 158°F). <br /> • Compatible with FlashScanO and CLIP protocol systems. UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), <br /> • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on suitable for installation in ducts. <br /> FlashScan systems). Relative Humidity: 10%-93%noncondensing. <br /> • Optional remote,single-gang LED accessory. <br /> • Dual LED design provides 360°viewing angle. Thermal Ratings: Fixed-temperature setpoint 1350F(570C). <br /> • Visible bi-color LEDs blink green every time the detector is DETECTOR SPACING AND APPLICATIONS <br /> addressed, and illuminate steady red on alarm (FlashScan sys- NOTIFIER recommends spacing detectors in compliance with NFPA <br /> tems only). 72. In low airflow applications with smooth ceiling, space detectors <br /> • Remote test feature from the panel. 30 feet (9.1 m). For specific information regarding detector spacing, <br /> • Walk test with address display(an address on 121 will blink the placement, and special applications refer to NFPA 72. System <br /> detector LED: 12-[pause]-1(F/ashScan systems only). Smoke DetectorApplication Guide,document A05-1003,is available <br /> • Built-in functional test switch activated by external magnet. at systemsensor.com <br /> • Built-in tamper-resistant feature. ELECTRICAL SPECIFICATIONS <br /> • Sealed against back pressure. Voltage Range: 15-32 volts DC peak. <br /> • Expanded color options. Standby Current(max. avg.): 200pA @ 24VDC(one communica- <br /> • SEMS screws for wiring of the separate base. tion every five seconds with LED enabled). <br /> • Optional relay,isolator,and sounder bases. LED Current(max.):4.5mA @ 24 VDC("OM'). <br /> Specifications Installation <br /> Sensitivity: FSP-951 series plug-in detectors use a separate base to simplify <br /> • UL Applications:0.5%to 4.0%per foot obscuration. installation,service,and maintenance. <br /> • ULC Applications:0.5%to 3.5%per foot obscuration. Mount base (all base types) on an electrical backbox which is at <br /> Size:2.0°(5.3 cm)high;base determines diameter. least 1.5° (3.81 cm)deep. For a chart of compatible junction boxes, <br /> see DN-60981. <br /> —B300-6:6.1°(15.6 cm)diameter. <br /> NOTE: 1) Because of inherent supervision provided by the SLC loop, <br /> —B501:4°(10.2 cm)diameter. end-of-line resistors are not required. Wiring 7-taps"or branches are <br /> For a complete list of detector bases see DN-60981. permitted for Style 4(Class`B)wiring.2) When using relay or sounder <br /> Shipping weight:3.4oz(96.4g) bases,consult the ISO-X(A)installation sheet 156-1380 for device limita- <br /> tions between isolator modules and isolator bases. <br /> Operating Temperature range: <br /> • FSP-951,0°C to 500C(320F to 1220F). <br /> • FSP-951T,0'C to 3B°C(32°F to 100°F). <br /> DN-60977:A•4/17/18—Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.