Laserfiche WebLink
DN-60918:A <br /> Indoor Selectable-Output <br /> Horns, Strobes, and Horn N OTI F I E R <br /> Strobes for Wall Applications by Honeywell <br /> AudioNisuall Devices-The L-Series offers the most versatile and easy-to-use line of <br /> horns,strobes,and horn strobes in the industry with lower cur- <br /> rent draws and modern aesthetics. With white and red plastic <br /> housings, standard and small footprint devices, and plain, <br /> FIRE-printed devices, L-Series can meet virtually any applica- <br /> tion requirement. <br /> The L-Series product line of wall-mount horns, strobes, and q <br /> horn strobes include a variety of features that increase their <br /> application versatility while simplifying installation. All devices <br /> feature plug-in designs with minimal intrusion into the back P2RL <br /> box, making installations fast and foolproof while virtually elim- <br /> inating costly and time-consuming ground faults. <br /> To further simplify installation and protect devices from con- <br /> struction damage, L-Series utilizes a universal mounting plate <br /> for all standard and compact models with an onboard shorting F F <br /> spring,so installers can test wiring continuity before the device j <br /> is installed. I I ' <br /> Installers can also easily adapt devices to a suit a wide range R . •..,� J ..�•�%,� � � R <br /> of application requirements using field-selectable candela set- E <br /> tings, automatic selection of 12- or 24-volt operation, and a � E <br /> rotary switch for horn tones with two volume selections. <br /> Features P2GWL SGWL <br /> • Updated modern aesthetics. <br /> • Small profile devices for Horns and Horn Strobes. <br /> • Plug-in design with minimal intrusion into the back box. <br /> • Tamper-resistant construction. <br /> • Automatic selection of 12-or 24-volt operation at 15 and 30 <br /> candela. , <br /> • Field-selectable candela settings on wall units: 15, 30, 75, <br /> 95, 110, 135,and 185. <br /> • Horn rated at 88+dBA at 16 volts. <br /> • Rotary switch for horn tone and two volume selections. >� _ <br /> • Universal mounting plate for all standard and all compact HWL <br /> wall units. <br /> • Mounting plate shorting spring checks wiring continuity. <br /> before device installation. <br /> • Electrically Compatible with legacy SpectrAlertP and 12 or 24 volts. When used with the Sync•Circuit Module, 12- <br /> SpectrAlert Advance devices. volt-rated notification appliance circuit outputs shall operate <br /> • Compatible with MDL3 sync module. between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit <br /> outputs shall operate between 16.5 and 33 volts. Indoor <br /> • Listed for wall mounting only. L-Series products shall operate between 32 and 120 degrees <br /> Fahrenheit from a regulated DC or full-wave rectified unaltered <br /> Architectural/Engineering Specifications power supply.Strobes and horn strobes shall have field-select- <br /> General: L-Series standard horns, strobes, and horn strobes able candela settings including 15, 30, 75, 95, 110, 135, and <br /> shall mount to a standard 2" x 4° x 17/8" back box, 4° x 4° x 185. <br /> 1'/2°back box,4°octagon back box, or double-gang back box. Strobe. The strobe shall be a L-Series Model listed to UL <br /> L-Series compact products shall mount to a single-gang 2° x 1971 and shall be approved for fire protective service. The <br /> 4° x 17/8° back box. A universal mounting plate shall be used strobe shall be wired as a primary-signaling notification appli- <br /> for mounting ceiling and wall products for all standard-size ance and comply with the Americans with Disabilities Act <br /> models and a separate universal mounting plate shall be used requirements for visible signaling appliances,flashing at 1 Hz <br /> for mounting compact wall models. The notification appliance over the strobe's entire operating voltage range. The strobe <br /> circuit wiring shall terminate at the universal mounting plate. light shall consist of a xenon flash tube and associated lens/ <br /> Also, L-Series products, when used with the Sync•CircuitTm reflector system. <br /> Module accessory, shall be powered from a non-coded notifi- <br /> cation appliance circuit output and shall operate on a nominal <br /> DN-6091 BA•2/3/2017—Page 1 of 4 <br />