Laserfiche WebLink
72-36 NATIONAL FIRE ALARM CODE Job# <br /> $• ALARM NOTIFICATION DEVICES AND CIRCUITS(continued) Permit# FIRE-0012612020 <br /> 8.4 Types and Quantities of Non-voice Notification Appliances Installed <br /> Bells: With Visual device: Horns: 18 With Visual device: 18 <br /> Chimes: With Visual device: Speaker: With Visual device: <br /> Visual devices without audible devices: 8 Other: <br /> 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED <br /> Hold-open door releasing devices Smoke management or smoke control Elevator recall <br /> [f Door Unlocking ❑Other: <br /> 10.SYSTEM POWER SUPPLY <br /> 10.1 Primary Power <br /> Nominal Voltage 120VAC Amps 3.2 Overcurrent protection type: Breaker Amps 20 <br /> Location(of primary supply Panelboard): Disconnecting means location: <br /> 10.2 Secondary Power <br /> Location: Bottom of FACP Type: Sealed Lead Acid Battery Nominal voltage: 24VDC <br /> Number of standby batteries: 2 Amp hour rating: 12 Current rating: <br /> Calculated capacity of secondary power to drive the system: In standby mode: 24 In alarm mode:5 <br /> Location of emergency generator: Location of fuel storage: F N/A <br /> 11.RECORD OF SYSTEM INSTALLATION <br /> Fill out after all installation is complete and wiring has been checked for opens,shorts,ground faults, and improper branching, but before <br /> conducting operational acceptance tests. <br /> The system has been installed in accordance with the following NFPA standards: (Note any or all that apply) <br /> NFPA-72,National Fire Alarm Code F,/ NFPA-70, National Electrical Code,Article 760 <br /> vj Manufacturer's published instructions Other(please specify): <br /> System deviations fro er ced NFPA standards: <br /> Signed: Printed name: Osvaldo Campos Date: 111812021 <br /> Organization: Criti ystem Solutions, LLC. Title: Installation Tech Phone: (727) 209-5122 <br /> 12.RECORD OF SYSTEM OPERATION <br /> All operational features and functions of this system were tested by or in the presence of the signer shown below,on <br /> the date shown below,and were found to be operating properly in accordance with the requirements of: <br /> C NFPA-72,National Fire Alarm Code rI 1,117PA-70, National Electrical Code,Article 760 <br /> Manufacturer's published instructions Other(please specify): <br /> Documentation in accorOfn with Inspection and Testing Form (Figure 10.6.2.3) is attached <br /> Signed: Printed name: Osvaldo Campos Date: 111812021 <br /> Organization: Critical Syst)n Solutions, LLC. Title: Installation Tech Phone: (727) 209-5122 <br /> FIGURE 4.5.2.1 Recor Completion NFPA 72(pg.4 of S) <br />