Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water,pipe insulation <br /> insulation for hot Water-pipe with a minimum thermal resistance (R.-value) of R-3 shall be applied to the <br /> following:. <br /> Piping�1; inch (19.1 mm) and larger,in.nominal diameter. <br /> Piping;serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to.a distribution manifold: <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A cony ofthe energy cacls shall be with permit at all times: <br /> 27. Cony of%al insulation retiort shall-be Provided with permit before rinaL <br /> 28:No fence,-Pool or screen enclosure Is issued with This permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />