Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot.water pipe insulation <br /> insulation for hot water pipe With'a minimum thermal resistance (R-value) of R-3 shall-be applied to the <br /> following:. <br /> Piping.31, inch (19:1 mm)and large rin.nominal diameter. <br /> Piping,serving more than:one dwelling unit. <br /> Piping located.outside the conditioned space. <br /> Piping from the water heater to a distribution manifold:- <br /> piping located under a floor slab. <br /> Buried in piping,- <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy of the energy cacls shall be with permit at all times <br /> 27.. Copu of rnal.insulation report shall be provided ivith permit before fnaL <br /> 28.No fence,pool onscreen'enclosure is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-.Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) . <br />