Laserfiche WebLink
D <br /> i <br /> Q' <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. FIRE. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall N graded to coriiply with R401:3 of the F:B.C: <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5-. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> T. All,property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> R. No electric,.plumbing; mechanical, or framing shall be covered without an:inspection and. <br /> approval first. <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).: <br /> i 1. Appliances shall not be installed in a location where subject to mechanical_damage unless <br /> protected by approved barriers. M303.:4 of the F.B.0 <br /> 12. water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1_ <br /> 14. Retutn air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors.are to be installed in accordance with R313-.1 of the F.B.C. <br /> 16. All'glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C.. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2U6 N:E.C. Codes will be enforced. <br />