Laserfiche WebLink
® . ® . G6ilCoa's1jQ <br /> SUPPLY & MANUFACTURING <br /> G U L F <br /> 26 GUAGE <br /> iTM PANEL OVER OVER 15/32" PLYWOOD <br /> FLORIDA PRODUCT APPROVAL NO. 11651.22 R3 <br /> TM <br /> ENGINEER LOAD TABLE:26 Ga.GulfRibTM Panel over 15/32"Plywood <br /> Buildings having a'Roof Mtiarr.Height<20'-0";,Roof Slope 2`'/12"- 1.2"712",.Gable o'r Hip`,Roof;Wind Speeds 1.20= <br /> 180rnph,.Exposure C, Risk Category,II, Endosed'Building 'based on-Florida--Building Code 2017., <br /> 120 130 140 150 160 170 180 <br /> WIIND FASTENER SUBSTRATE <br /> SPEED (MIN.1/4" (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER <br /> Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING <br /> ZONE 1 #9-15x1.5" Plywood ` 24:';TYPE 1 -24";TYPE'1..24"'TYPE 1' 24';TYPE 1 24";TYPE 1:' 24 ,TYPE T, '-24 TYPE,1,'. <br /> ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 2 <br /> ZONE 3 #94.5x.'5" . ,:Plywood, 24",.TYPE 1. =24",TYPE 1.=. ,247,TYPE 1 12 TYPE 2 12'.',TYPE 2` 12 :TYPE 2 ,12 TYPE 2 <br /> 1.)PANEL DESCRIPTION:GULFRIBTM, MIN.26 GA.,GRADE 80,36"COVERAGE,3/4"TALL. <br /> 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL <br /> 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 <br /> PSF @ 12" O.C.FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. <br /> 4.)PLYWOOD DECKING:MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. <br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. <br /> 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING <br /> CODE 2017. <br /> zONE2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or <br /> — ZONE (1 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be <br /> ------- <br /> ----------- <br /> ' a less than either 4%of the minimum width of the building or 3 feet. <br /> TYPE 1 FASTENER PATTERN <br /> RIDGE' /// // j 9° 9" 9" �Laip <br /> -- ------� // 4 At <br /> / ZONE 1 \\\\ L Cont Tape Seal for use on Slopes less than 3:12 <br /> (1)#9-15 x 1-1/2°w/Sealer Washer @ 24.O.C.Max. <br /> / \ <br /> SAVE <br /> TYPE 2 FASTENER PATTERN <br /> ZONE 2 GABLE ROOF 1a1 �6.5"—{2.5°{-6.5"—{2.5° 6.5"�{2.5"{-6.5"—{2.5° <br /> / I I <br /> RIDGE L Cont.Tape Seal(or use on Slopes less than 3:12 <br /> _—_-- (1)#9-15x1-1/2'w/Sealer Washer @12°O.C.Max. <br /> 14----------------------�. a <br /> I <br /> ZONE 1 <br /> i <br /> `\t <br /> "�ZONE3 EAVE <br /> FL#11651.22 R3•OCTOBER 5,2017 <br /> PRO.DUCT EVALUAXION REPORT <br /> •• '• • RATON. FL 33487 FL COA <br />