My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1297
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1297
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 3:41:16 PM
Creation date
6/1/2022 10:08:26 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-1297
Building Department - Name
HARRIS,ROBIN
Address
5150 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUPPLY & MANUFACTURING <br /> p PRO DUtT"APPROVWL G61iCozk <br /> LORIDA <br /> G U LF .-] ,--, <br /> 26 GUAGE GULFRIBTKI <br /> PANEL OVER • • <br /> O. D . PRODUCT APPROVAL NO. 11651.22 F' ? <br /> fM <br /> Code Compliance: The product described herein has demonstrated compliance with the <br /> Florida Building Code 2017, Sections 1504.3.2. <br /> Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load <br /> requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. <br /> Performance Standards: The product described herein has demonstrated compliance with: <br /> • UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> • UL 1897-12 - Uplift Test for Roof Covering Systems. <br /> Reference Data: 1. UL 580-94/1897-98 Uplift Test <br /> Force Engineering &Testing, Inc. (FBC Organization#TST-5328) <br /> Report No. 117-0062T-07A, B, Dated 02/19/2007 <br /> 2. Certificate of Independence <br /> By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC <br /> (FBC Organization#ANE ID: 10743) <br /> Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test <br /> standard. <br /> Quality Assurance Entity: The manufacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Rule 61 G20-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved quality <br /> assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including <br /> Section 1507.4.2 and in accordance with Manufacturers recommendations. For <br /> slopes less than 3:12, lap sealant must be used in the panel side laps. <br /> Installation: Install per Manufacturer's recommended details. <br /> Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. <br /> FL#11651.22 R3•OCTOBER 5,2017 <br /> . ® ® EVALUATION REPORT <br /> . <br /> ENGINEERING,KUHN <br />
The URL can be used to link to this page
Your browser does not support the video tag.