Laserfiche WebLink
DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />SEE ROOF <br />PLAN SHEATHING <br />BLOCKING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />A <br />G.T. <br />CONTINUOUS LATERAL <br />ADD 2X4 ALONGSIDE <br />BRACING- NAIL OVER <br />TOP CHORD WHEN REQ'D <br />X-BRACE AS SHOWN - <br />TO PREVENT PLYWOOD <br />INSTALL BLKG. AT TRUSS <br />X-BRACING - 2x4 SPF OR <br />SPAN FROM EXCEEDING <br />PACK <br />WEBS FOR NAILING <br />SYP wi 2 isa @ EACH TRUSS <br />MAX 24" SPAN (EITHER <br />US <br />WEB <br />SIDE OR BOTH IF REQ'D) <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER <br />w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. CONSTRUCTION THIS D <br />H ON LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />(2) 12D NAILS —} <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL r2 <br />SCALE: 1 /2"=V-0" <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLKING. NAILED @ EACH <br />SIDE w/ 3 d NAILS WHEN <br />12 <br />REQUIRED w/ (2) SIMPSON HTS20 <br />W/ (14) -10d X 1 1/2" EACH <br />IT[ 41: T[ 14 <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT —TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg B <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />1 A CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />— -/—WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1/2"=V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR _ <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 j <br />DIAGONAL <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />M3 <br />HIP <br />G.T <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT—/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @a INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />2) SIMPSON SDWC15600 SCREWS PROVIDE 25" LAP <br />( @ SPLICE @ F.C. REBAR <br />EACH TRUSS TO LEDGER <br />1/2" GYP. WB <br />OR 3/8" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />COMMON @ 6" O/C TO ONE SIDE OF THE <br />FLOOR TRUSS FOR AN <br />AREA <_ 1000 SQ. FT. OF <br />FLOOR AREA & SEALED <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />SHALL DIVIDE THE <br />CONCEALED SPACE INTO <br />APPROX. EQUAL AREAS. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />FLOOR CONNECTION c�, EXTERIOR <br />TOP -CHORD BEARING <br />FLOOR TRUSSES @ <br />24" O.C. <br />2) 2x8 SYP #2 P.T. <br />LEDGER ATTACHED TO <br />MASONRY w/ (2) ROWS <br />1/2" SIMPSON TITEN HD, <br />MIN. 5" EMBEDMENT PER <br />54/D1 SPACING. <br />WALL 53 <br />- <br />SCALE: 3/4" = V-0" <br />SCALE: 1/2" = V-0" <br />2'-0" MIN. <br />LAP SPLICE <br />6" 6" 1'-0" 6" 6" <br />TYP. TYP. <br />0 0 1 0 0 0 0- <br />SPLICE <br />0 I 0 0 0 <br />Z-0" SPLICE BEYOND Z-0" <br />PART. ELEV. VIEW <br />PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />/—(2) ROWS OF 10d NAILS @ 4" O.C. <br />FLOOR TRUSSES <br />@ 24" O.C. <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />(2)-1/2" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0" O.C. T & B <br />FLOOR ATTACHMENT(50 <br />SCALE: 3/4" = V-0" <br />WOOD TRUSS <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION.—-,, <br />PRE-ENGINEERED ROOF —� <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"X24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />n nrrrr.i c.-rninn <br />MASO' <br />SEE P <br />DETAIL - ADJACENT TO TRUSSES <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />M\_17.a T(1CAIAILS <br />2X6 P.T. CONT. <br />_EDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />D.C. T&B <br />TRUSS <br />(6) .162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />w/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />MIN. 2x4 #2 SPF P.T. <br />CONT. W/ (2) a'x3" <br />TITEN2 SCREWS @ <br />16" O.C. <br />TRUSS OR <br />TROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL 52 <br />SCALE: 3/4" = 1'-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />I:EEMUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />LEV, MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING.—� <br />2X4 BLOCKING @ 48" O.C. MAX. W/ <br />30 LB FELT (SHINGLES) <br />(2) 16d TOE NAILS @ EACH END <br />FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK <br />SHEATHING 4' ON EA. SIDE <br />RUNNER TO SHEATHING <br />ABOVE AT EACH SIDE <br />OF WALL NOT STAGGERED <br />OVER PARTY WALL <br />CEILING BOARD <br />2x4 LEDGER @ 48" O.C. <br />SEE ROOF PLAN <br />MAX VERTICALLY NAILED <br />FOR STRAP INFO. <br />TO TRUSS WEBS W/ (2) 8d <br />BASE BOARD PER SPECS. <br />4P <br />(TYP.) <br />a a I <br />EXTEND BURN CLIPS AS PER <br />2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. <br />FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. SPECIFICATIONS NAILED INTO <br />W/ (2) 1/4"x3" TITEN2 <br />o ° <br />2x4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />(2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH <br />SCREWS @EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" <br />LEDGER <br />STD 909 HOOK <br />DRYWALL NAILS OR DRYWALL <br />SCREWS 7" O.C. EDGES. <br />SIMPSON RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS <br />3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" <br />SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS TO BE INSTALLED PRIOR TO FURRING STRIPS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR d INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />UL-U905 see sht 9 LOCATIONS) <br />( ) 1x P.T. NAILER INSTALLED <br />1 <br />2 x P.T. BLOCKING BY FRAMER FOR i <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />SEE 53/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ <br />8d COMMON AT 6" O.C. TO ONE SIDE OF TOP CH I <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. 00 S TEI <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP.—// <br />(OR 518" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />0 EDGES <br />6" 6" 16" O.C. <br />DBL. KO. BLOCK MIN. MIN. TYP(2) 2x8 SYP #2 P.T. CONT. <br />T <br />T <br />a <br />24" MIN. <br />(2) 2x8 P.T. <br />ATTACHED <br />LEDGER w/ (2) ROWS OF 1/2" <br />TITEN HD STAGGERED@ 24" <br />O.C. w/ 5 EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICE TOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />• • •Sr <br />- ••r <br />. 1 <br />- <br />1 • • ` - � <br />w full <br />••- • - : r <br />.. • , - , <br />a <br />III <br />_,l <br />� ����� <br />a. <br />`—DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA. COURSE FILLED W/ GROUT <br />1" P.T. NAILER <br />R-3 MIN. INSUL. PER. FBC. <br />GYP. WB. <br />(1) #5 VERT. IN FILL CELLS (SEE TYP. "S" MORTAR (TYP.) <br />FOUNDATION PLAN FOR LOCATIONS) <br />U <br />8" CONC. BLOCK (TYP.) PER UL905 a <br />1x P.T. BASE NAILER N a <br />6x6 W1.4xW1.4 WWF. g 4"x4" INSPECTION PORT. AT <br />EACH FILLED CELL (TYP.) <br />S <br />0 <br />(4) #5 CONT. STD. 90° HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) <br />2-STORY PARTY WALL SECTION (PWO <br />SCALE: 3/4"=V-0" <br />FLOOR TRUSS' AT <br />24" O.C. <br />GYP. BOARD CLG. <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. ---_ <br />(2)-1 X 4 P.T. BASE —� <br />NAILER <br />BASE BOARD <br />PER SPECS. �� <br />CONC. SLAB <br />SEE FOUND. PLAN---- <br />6 MIL VISQUEEN —� \ <br />1 0 / <br />SEE PLAN <br />TOP OF PLATE <br />STOP COURSE W/ <br />�— LINTEL SEE <br />PLAN <br />_ SEE PLAN <br />TOP OF WINDOW <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />10'-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />00 <br />TREATED SOIL <br />i N <br />3 #5 CONT. 20" <br />Ill,, <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />F.F. <br />VARIES WITH <br />SITE GRADES <br />SEE PLAN <br />4_. 0 <br />01 <br />O y <br />® C C%1 <br />. C) <br />-74 <br />0 <br />s <br />LLI <br />°'•c1SE� <br />.a • N <br />rro <br />A ......... •••• �. <br />O"� <br />,� <br />,a�`° <br />To the best of the En i ee s knowledge. o n ra Howl d e information and belief, <br />9 9� , <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />'ItE <br />0 <br />11- .0 8 <br />0 <br />u�'�� <br />0 - �� �� <br />(0� <br />��� <br />ai HMV zS W <br />4 C J Z W W <br />J u �+ 5 a. <br />1 <br />11 W <br />Z <br />9 <br />N N O �c <br />U) 91 m W <br />Z `n MZ a J <br />tLW <br />N - <br />O <br />Z O U <co <br />W a❑ <br />z N o <br />�o <br />Z � N <br />z o � <br />M <br />z <br />�.1 <br />Q) <br />4.1 <br />° <br />0, U <br />O—� <br />r, r o <br />N 01- w <br />�V) <br />U � <br />1- J E <br />is Lu <br />U <br />� <br />w <br />M <br />M <br />�' � <br />w <br />Z <br />Z <br />Q E <br />E o <br />_'p <br />o= <br /><� <br />Z® <br />m <br />o <br />wo <br />DU <br />z~ <br />CV <br />I. o <br />rz <br />wo <br />O Q <br />w= <br />¢ <br />a > L <br />Q O <br />m <br />. <br />(n ro C <br />zY <br />0 <br />zL�iLL <br />N <br /><w <br />o� <br />Z 1z <br />o <br />gu <br />MINa <br />wLL <br />g <br />�w <br />J <br />o <br />Jz <br />w, <br />'3 <br />>° <br />z< <br />a <br />°§ <br />2 C)0 <br />y <br />> C� <br />N <br />CD <br />co <br />r <br />T <br />N <br />le) <br />L <br />(0 CIO <br />o <br />CIO <br />In <br />CN <br />C.0 <br />60 <br />v, m <br />O <br />r <br />4-0 <br />o <br />cfl <br />r <br />C) rn <br />,-- <br />cu <br />�; L <br />o <br />Z <br />z <br />O <br />ILU <br />s <br />Q p <br />JOB NO : 22-05610-05605 <br />SCALE : AS NOTED <br />SHEET NO. <br />D1 <br />