My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36459 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36459 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 2:54:34 PM
Creation date
1/21/2025 3:30:59 PM
Metadata
Fields
Template:
Building Plans
Street #
36459
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
4735
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - �:' i aA - , - _- .-_:—T. _�__—._.. —. .':...- <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />�J P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />Inv" <br />FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />❑TV <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />I� <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C`�0 <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />jIL <br />I <br />I <br />i <br />I <br />I <br />l / I HANSON <br />BOX <br />I I <br />� I I <br />LAV _T\ <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />OPT <br />LAV <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />Power Co. Feed <br />Intersystem Bonding <br />Termination Per <br />DISCONNECT <br />OUTDOOR-LIVINGM. <br />INSTALL LIGHT �`�> <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />GFI <br />\ lilllll Illilli ii I ill <br />GFI <br />I DEDICATED RECEPTACLE <br />DINING ` I FOR MICROWAVE RANGE <br />I HOOD PER SPECS <br />I <br />KITCHEN 1 <br />I <br />� I <br />� FI �0 rGIE1_J <br />--tGFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK C.M <br />� II <br />\ I <br />I <br />GREAT ROOM <br />/,,>ROUGH -IN <br />FOR OPT. CH <br />FAN/LIGHT' <br />I , <br />UPSTAIRS <br />1 / <br />_ I <br />FOYER G <br />\ GFI <br />@ 44" W.H. <br />— / A.F.F. ` O <br />I / I <br />ENtRY I WPDB I GARAG E <br />LIGj-IT AS b FI f <br />PER SPECS <br />DB&GFI TO <br />BE ALIGNED — GARAGE <br />VERTICALLY LIGHT AS <br />PER SPECS <br />GARAGE <br />---DOOR <br />I GFI <br />I -- r- — — — — — — — — — — — — — — — -- <br />I I <br />I I I <br />I � I <br />bZ j <br />200A re X W U_ I <br />Indoor Panel H <br />Center W ZO ��/ A j 0 <br />U <br />NEMA 1 \ L}L F W I <br />200 AMP \ U W <br />>0m Dw I <br />ETER MA N <br />1 0-200 A P Serial Cable \ � — <br />NEMA ` COACH LIGHTS <br />3R OR PREWIRE AS <br />\ _ �--7— #4 Solid COPPER Ground PER SPECS <br />NEC 17, 250.94 L5/8" Galvanized Driven Ground J <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE: YV=V-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: %4'=V-0" <br />;�Q'. <br />co <br />t) <br />cli <br />fV <br />._: <br />CZU L-L <br />-0 :CD y <br />f <br />C-) <br />N v <br />- _ 05 <br />w � Q <br />0_ <br />' ,. <br />CL <br />tc5 O O <br />FL LU <br />CN <br />O <br />CV <br />M <br />CV <br />CV <br />0 <br />�,.... <br />1,! P 1...E <br />..I <br />N <br />... <br />��E <br />No P� 7�0 <br />44 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and sea] is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W <br />a <br />E <br />o 8 (co, <br />p N OD J <br />V <br />00 to � � LL IlJ <br />� <br />c14 o a — <br />a <br />J LL LL d. Lu <br />Z <br />= °' O <br />_ <br />_ <br />cc <br />Z <br />IL <br />_jW o a�00 ZNN <br />ZO <br />Cl), lY y O <br />. . <br />U U_j U) <br />W <br />❑ ❑ ❑ <br />z N <br />o <br />Z m <br />QQN <br />z O Q <br />J — <br />(L � <br />V ! <br />''nn �6 <br />V O <br />� <br />w <br />—� <br />O <br />I /) <br />w <br />IUO <br />U <br />w <br />— � <br />8 <br />z I <br />U o <br />WOD <br />to, <br />14 <br />co <br />oW <br />co <br />co <br />¢ <br />Q <br />Z <br />U_ <br />E <br />:1- <br />o <br />O <br />wz <br />QN <br />Z <br />as <br />tt <br />a Q <br />0CID <br />2 Q <br />N <br />r <br />¢OwZ <br />¢m0 <br />oz" <br />z <br />ag-1 <br />C <br />O <br />mz <br />WFZ <br />z°<o0LL <br />Q <br />W w <br />dz <br />N W <br />U¢o <br />aLL <br />�k <br />'3 <br />o <br />�� <br />=, <br />ao <br />M <br />o <br />0 O <br />L <br />2 <br />F_ <br />rn <br />c�a <br />L� <br />T <br />N <br />Co � <br />N <br />r <br />`_ <br />N <br />00 <br />U <br />rn <br />v l m <br />N <br />�t <br />1— <br />O <br />N <br />LO <br />N <br />r <br />N <br />Lb <br />G� <br />CO <br />r <br />aizL <br />M <br />CV <br />N <br />i» N <br />o <br />z <br />Z <br />E (N <br />M <br />a <br />E <br />U _j <br />Q 0 <br />C: <br />� <br />JOB <br />NO: 22-02407-02402 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />11.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.