11"InNiFf1m. � <br />r <br />1 <br />0 <br />7NC <br />ig W <br />N <br />UNIT 5-1 UNIT 5— UNIT 5-3 UNIT 5-41 <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE <br />ALL APPLICABLE LOCAL ORDINANCES AND IN COOPERATION WITH THE <br />UTILITY COMPANIES. <br />2. COORDINATE ALL WORK WITH ALL TRADES. <br />3. MOUNT ALL OUTLETS AND RECEPTACLES PLUMB AND FLUSH WITH WALLS. <br />4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN OTHERWISE. <br />5. INSTALL ELECTRICAL CABLE, WIRE AND CONNECTORS AS INDICATED IN <br />ACCORDANCE WITH THE MANUFACURERS WRITTEN INSTRUCTION,THE <br />APPLICABLE REQUIREMENTS OF NEC AND THE NATIONAL ELECTRICAL <br />CONTRACTORS ASSOCIATION "STANDARD OF INSTALLATION" AND <br />IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE <br />THAT PRODUCTION SERVE THE INTENDED FUNCTIONS. <br />6. ALL WE SHALL BE STD. P0 AND #12 AND SHALL BE ROMEX OR NM <br />CABLE TYPE B OR APPROVED EQUAL. <br />7. COORDINATE ELECTRICAL REQUIREMENTS FOR A/C WITH A/C CONTRACTOR. <br />8. ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFCI <br />(ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT. <br />ELECIRRIC UTILITY Co. — <br />TO <br />UTILITY COY ELECDTRIC <br />40 gR(UI M SURFAMOUNT <br />PANEL—i <br />200 <br />AMP <br />C WITH 3-IdO THW AL <br />#4 CU. GROUN <br />TO COLD WATER LINE <br />5/8" X 8" GROUND LINE <br />( ASC0 CO. ATTACH TO FOOTER REBAR) <br />(BACK TO BACK SERVICE/OFFSET SIMILAR) <br />1200 AMP ELECTRICAL RISER <br />N.T.S. <br />0 <br />S <br />Ln <br />N <br />Q <br />LS <br />Lq- <br />dEE <br />7 <br />